Pepperl+Fuchs SLPC8-2/31
Safety light grid with integrated control unit
- Sensing range up to 8 m
- 2-radial design
- Beam spacing 500 mm
- Self-monitoring (type 4 according to IEC/EN 61496-1)
- Minimum wiring expense due to transceiver with passive mirror column
- Red transmission light
- Usable with or without start/restart disable
- Integrated relay monitor
- 7-segment diagnostic display
- Pre-fault indication
- OSSD outputs as semiconductor or relay outputs
- Overview
- Comments
Angle of divergence | < 5 В° |
Function indicator | LED red: per receiver channel off: interruption flashes: receiver continuously on: reception with sufficient stability control on the front plate: LED red: OSSD off LED green: OSSD on |
Mirror pillar | SLP8-2-M |
Performance level (PL) | PL e |
Connection | M16 cable gland , terminal compartment with cage-terminals |
Category | Cat. 4 |
Degree of protection | IP65 |
Number of beams | 2 |
PFHd | 3.54 E-9 |
Pre-fault indicator | LED red next to receiver flashes |
Safety output | 2 relay outputs, force-guided NO-contact |
Mission Time (TM) | 20 a |
Light source | LED |
Signal output | 1 PNP each, max. 300 mA for start readiness, OSSD on, OSSD off |
Functional safety | ISO 13849-1 |
Transceiver | SLPC8-2-A/31 |
Target size | static: 32 mm dynamic: 50 mm (at v = 1.6 m/s of the obstacle) |
Effective detection range | 0.2 ... 8 m |
Switching current | 0.01 ... 2 A |
Product standard | EN 61496-1 ; IEC 61496-2 |
Function input | Relay monitor, start release |
B10d | see instruction manuals |
Marking | CE |
Operating voltage | 24 V DC -15% / +25% , galvanically isolated |
Operating mode | Start/restart disable, relay monitor, |
Safety type according to IEC/EN 61496 | 4 |
Beam spacing | 500 mm |
Light type | modulated visible red light |
Switching voltage | 20 ... 60 V DC, 12 ... 25 V AC rms |
Diagnostics indicator | 7-segment display |
People also buy
Comments
No comments yet