Pepperl+Fuchs SLPCM10-3-L/31
Safety light grid with integrated control unit

Pepperl+Fuchs SLPCM10-3-L/31

The Product is out of Production!

Contact the manager for more information.

  • Sensing range up to 10 m
  • 3-radial design
  • Beam spacing 400 mm
Item Number: SLPCM10-3-L/31
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments

The Product is out of Production!

Contact the manager for more information.

Specification:

  • Sensing range up to 10 m
  • 3-radial design
  • Beam spacing 400 mm
  • Self-monitoring (type 4 according to IEC/EN 61496-1)
  • Red transmission light
  • Usable with or without start/restart disable
  • Sequential and parallel muting in various operating modes
  • Emergency muting for the correction of the material jam
  • Integrated relay monitor
  • 7-segment diagnostic display
  • Integrated function display
  • Pre-fault indication
  • OSSD outputs as semiconductor or relay outputs

Datasheet:

  • ReceiverSLPCM10-3-R-L/31
  • Switching voltage: 20 ... 60 V DC, 12 ... 25 V AC rms
  • Signal output: 1 PNP each, max. 300 mA for startup readiness, OSSD on, OSSD off, muting lamp, signals in parallel in the lamp socket
  • Light type: modulated visible red light
  • PFHd: 3.54 E-9
  • B10d: see instruction manuals
  • Diagnostics indicator: 7-segment display
  • Switching current: 0.01 ... 2 A
  • Function indicator: LED red: per receiver channel; off: interruption; flashes: receiver; continuously on: reception with sufficient stability control
  • on the front plate
  • LED red: OSSD off
  • LED green: OSSD on
  • LED yellow: types of muting operation
  • Category: Cat. 4
  • Connection: M16 cable gland, terminal compartment with cage terminals, M12 connector for transmitters, muting lamp, etc., muting sensors, lamp socket for muting lamp, etc.
  • Pre-fault indicator: LED red next to receiver flashes
  • Number of beams: 3
  • Angle of divergence: < 5 В°
  • Light source: LED
  • Operating voltage: 24 V DC -15% / +25% , galvanically isolated
  • Degree of protection: IP65
  • Function input: Relay monitor, start release, muting sensors (max. 4)
  • Functional safety: ISO 13849-1
  • Safety type according to IEC/EN 61496: 4
  • Mission Time (TM): 20 a    
  • Safety output: 2 relay outputs, force-guided NO-contact    
  • Performance level (PL): PL e    
  • Effective detection range: 0.2 ... 10 m    
  • Beam spacing: 400 mm    
  • Operating mode: Start/restart disable, relay monitor, muting operating modes    
  • Target size: static: 32 mm
  • dynamic: 50 mm (at v = 1.6 m/s of the obstacle)    
  • Emitter: SLP10-3-T    
  • Product standard: EN 61496-1 ; IEC 61496-2    
  • Marking    CE

Comments

No comments yet

Write a comment