Pepperl+Fuchs UB200-12GM-I-V1
Ultrasonic sensor
- Analog output 4 mA ... 20 mA
- Very small unusable area
- Measuring window adjustable
- Program input
- Temperature compensation
Item Number:
UB200-12GM-I-V1
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Adjustment range | 20 ... 200 mm |
Dead band | 0 ... 15 mm |
Repeat accuracy | В± 0.5 % of full-scale value |
Temperature influence | В± 1.5 % of full-scale value |
Response delay | approx. 30 ms |
CCC approval | CCC approval / marking not required for products rated 36 V |
LED red | solid red: Error red, flashing: program function, object not detected |
No-load supply current | 30 mA |
Input type | 1 program input lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kandOmega;, pulse duration: 1 s |
Sensing range | 15 ... 200 mm |
Deviation of the characteristic curve | В± 1 % of full-scale value |
Mass | 25 g |
Output type | 1 analog output 4 ... 20 mA |
Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Standard target plate | 100 mm x 100 mm |
LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
Transducer frequency | approx. 400 kHz |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Connection type | Connector M12 x 1 , 4-pin |
UL approval | cULus Listed, Class 2 Power Source |
Resolution | 0.17 mm |
Degree of protection | IP67 |
Load impedance | 0 ... 200 andOmega; |