Pepperl+Fuchs UB500-F54-I-V15
Ultrasonic sensor
- Analog output 4 mA ... 20 mA
- Measuring window adjustable
- Program input
- Synchronization options
- Deactivation option
- Temperature compensation
Item Number:
UB500-F54-I-V15
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
CSA approval | cCSAus Listed, General Purpose |
Output type | 1 analog output 4 ... 20 mA |
LED green | solid green: monitoring system green flashing: program function |
Transducer frequency | approx. 380 kHz |
Mass | 100 g |
Input type | 1 program input lower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kandOmega;, pulse duration: 1 s |
Repeat accuracy | В± 0.1 % of full-scale value |
LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
Adjustment range | 50 ... 500 mm |
Temperature influence | В± 1.5 % of full-scale value |
UL approval | cULus Listed, General Purpose |
Degree of protection | IP65 |
Connection type | Connector M12 x 1 , 5-pin |
Deviation of the characteristic curve | В± 1 % of full-scale value |
Sensing range | 30 ... 500 mm |
Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
Resolution | 0.13 mm |
Synchronization | 1 synchronous input 0 level: UB...+1 V 1 level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: 0.1 ... 8 ms |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Dead band | 0 ... 30 mm |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
CCC approval | CCC approval / marking not required for products rated 36 V |
No-load supply current | 55 mA |
Default setting | evaluation limit A1: 50 mm evaluation limit A2: 500 mm |
Standard target plate | 100 mm x 100 mm |
Response delay | 50 ms |
LED red | flashing: normal mode: error Program function: no object detected permanently: Program mode, object uncertain |
Load impedance | 0 ... 300 Ohm |
People also buy