Pepperl+Fuchs UC2000-30GM-E6R2-V15
Ultrasonic sensor

Pepperl+Fuchs UC2000-30GM-E6R2-V15
  • Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 3000
  • 2 programmable switch outputs
  • Hysteresis mode selectable
  • Window mode selectable
  • Synchronization options
  • Adjustable acoustic power and sensitivity
  • Temperature compensation
Item Number: UC2000-30GM-E6R2-V15
326.04
-
+
Total price: 326.04
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Synchronizationbi-directional
0 level -UB...+1 V
1 level: +4 V...+UB
input impedance: > 12 KOhm
synchronization pulse: 100 micro/s, synchronization interpulse period: 2 ms
Mass140 g
CSA approvalcCSAus Listed, General Purpose
Voltage drop 2.5 V
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
CCC approvalCCC approval / marking not required for products rated 36 V
Operating voltage10 ... 30 V DC , ripple 10 %SS
Switching frequency 2.5 Hz
Response delay65 ms minimum
195 ms factory setting
Temperature/TEACH-IN connectorTemperature compensation , Switch points programming , output function setting
Standard target plate100 mm x 100 mm
No-load supply current 50 mA
LED yellow 2solid: switching state switch output 2
flashing: program function
Output type2 switch outputs PNP, NO/NC, programmable
Range hysteresis1 % of the adjusted operating range (default settings), programmable
Degree of protectionIP65
Connection typeConnector M12 x 1 , 5-pin
LED yellow 1solid: switching state switch output 1
flashing: program function
EAC conformityTR CU 020/2011
UL approvalcULus Listed, General Purpose
LED redsolid: temperature/program plug not connected
flashing: fault or program function object not detected
Dead band0 ... 80 mm
Interface typeRS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
Temperature influence 2 % from full-scale value (with temperature compensation)
0.2 %/K (without temperature compensation)
Adjustment range120 ... 2000 mm
Rated operating current200 mA , short-circuit/overload protected
LED greensolid: Power-on
flashing: Standby mode or program function object detected
Repeat accuracy 0.1 % of full-scale value
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Transducer frequencyapprox. 180 kHz
Sensing range80 ... 2000 mm

Comments

No comments yet

Write a comment