Pepperl+Fuchs UC2000-30GM-IU-V1-HB
Ultrasonic sensor

Pepperl+Fuchs UC2000-30GM-IU-V1-HB
We ship to United States of America!
  • Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 3000
  • Analog current and voltage output
  • Adjustable acoustic power and sensitivity
  • Temperature compensation
  • UL and CSA NRTL certified for hazardous area installation
Item Number: UC2000-30GM-IU-V1-HB
765.11
-
+
Total price: 765.11
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Temperature influence 2 % from full-scale value (with temperature compensation)
0.2 %/K (without temperature compensation)
Load impedancecurrent output: 500 Ohm
voltage output: 1000 Ohm
LED yellow 1solid: object in evaluation range
flashing: program function
LED yellow 2solid: object in detection range
flashing: program function
UL approvalall Div 2 hazardous areas
Interface typeRS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
Sensing range80 ... 2000 mm
NoteIndividual components: UC-2000-30GM-IUR2-V15; V1-G-2M-PVC; M-106 impact adapter; ADAPT-ALUM*-M30X1/2"" NPT/HB****
Power consumption 900 mW
Operating voltage10 ... 30 V DC , ripple 10 %SS
Dead band0 ... 80 mm
Transducer frequencyapprox. 180 kHz
Output type1 current output 4 ... 20 mA
1 voltage output 0 ... 10 V
Connection typeCable connector , M12 x 1 , 5-pin , 4-wire
Deviation of the characteristic curve 0.2 % of full-scale value
CCC approvalCCC approval / marking not required for products rated 36 V
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Resolutionevaluation range [mm]/4000, but 0.35 mm
LED greensolid: Power-on
flashing: Standby mode or program function object detected
Response delay65 ms minimum
195 ms factory setting
Repeat accuracy 0.1 % of full-scale value
LED redsolid: temperature/program plug not connected
flashing: fault or program function object not detected
Degree of protectionIP65
Temperature/TEACH-IN connectorTemperature compensation , Evaluation range programming , output function setting
Standard target plate100 mm x 100 mm
CSA approvalNRTL certified
all Div 2, Class II Div 1, Class III Div 1 hazardous areas
Adjustment range120 ... 2000 mm
StandardsEN 60947-5-2
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)

Buy Pepperl+Fuchs UC2000-30GM-IU-V1-HB with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com offers electrical items wholesale online. We offer a huge industrial automation products list. We ship to every country with the shortest possible terms. We provide discounts of 5% or more to regular customers. We've made it easy for you to find spare parts. We have an individual approach to each client's needs and pay maximum attention to solving them.