Pepperl+Fuchs UC300-30GM-IUR2-V15
Ultrasonic sensor

Pepperl+Fuchs UC300-30GM-IUR2-V15
We ship to United States of America!
  • Very small unusable area
  • Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 3000
  • Analog current and voltage output
  • Synchronization options
  • Adjustable acoustic power and sensitivity
  • Temperature compensation
Item Number: UC300-30GM-IUR2-V15
396.91
-
+
Total price: 396.91
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
LED yellow 1solid: object in evaluation range
flashing: program function
Transducer frequencyapprox. 380 kHz
Dead band0 ... 15 mm
Deviation of the characteristic curve 0.2 % of full-scale value
Operating voltage10 ... 30 V DC , ripple 10 %SS
LED greensolid: Power-on
flashing: Standby mode or program function object detected
CCC approvalCCC approval / marking not required for products rated 36 V
Ambient temperature0 ... 70 В°C (32 ... 158 В°F)
Interface typeRS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
Outputevaluation limit A1: 15 mm
evaluation limit A2: 300 mm
rising ramp
Sensing range15 ... 300 mm
Mass170 g
Resolutionevaluation range [mm]/4000, but 0.05 mm
Temperature/TEACH-IN connectorTemperature compensation , Evaluation range programming , output function setting
Adjustment range15 ... 300 mm
LED redsolid: temperature/program plug not connected
flashing: fault or program function object not detected
Output type1 current output 4 ... 20 mA
1 voltage output 0 ... 10 V
Power consumption 900 mW
LED yellow 2solid: object in detection range
flashing: program function
CSA approvalcCSAus Listed, General Purpose
Time delay before availability 500 ms
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Repeat accuracy 0.1 % of full-scale value
UL approvalcULus Listed, General Purpose
Response delay21 ms minimum
63 ms factory setting
Load impedancecurrent output: 500 Ohm
voltage output: 1000 Ohm
Temperature influence 2 % from full-scale value (with temperature compensation)
0.2 %/K (without temperature compensation)
Degree of protectionIP65
Standard target plate100 mm x 100 mm
Synchronizationbi-directional
0 level -UB...+1 V
1 level: +4 V...+UB
input impedance: > 12 KOhm
synchronization pulse: 100 micro/s, synchronization interpulse period: 2 ms
Connection typeConnector plug M12 x 1 , 5-pin
EAC conformityTR CU 020/2011

Buy Pepperl+Fuchs UC300-30GM-IUR2-V15 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is an online electronic supply store. We offer only original products with all manufacturer's warranty. All your orders and products can be shipped in one delivery. Good price and good delivery times are our main goals. We always make open communication with our customers. Make an order and we will give you the best possible proposal.

Comments

No comments yet