Pepperl+Fuchs UC4000-30GM-2EP-IO-V15
Ultrasonic sensor

Pepperl+Fuchs UC4000-30GM-2EP-IO-V15
  • IO-link interface for service and process data
  • Programmable via DTM with PACTWARE
  • 2 programmable switch outputs
  • Selectable sound lobe width
  • Synchronization options
  • Temperature compensation
Item Number: UC4000-30GM-2EP-IO-V15
390.32
-
+
Total price: 390.32
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Process data witdh16 bit
Adjustment range240 ... 4000 mm
Rated operating current200 mA , short-circuit/overload protected
Standard target plate100 mm x 100 mm
Input/output type1 synchronization connection, bidirectional
LED redsolid red: Error
red, flashing: program function, object not detected
Range hysteresis1 % of the adjusted operating range (default settings), programmable
CCC approvalCCC approval / marking not required for products rated 36 V
Response delayminimum : 115 ms
factory setting: 225 ms
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Power consumption 1 W
Operating voltage10 ... 30 V DC , ripple 10 %SS
ProtocolIO-Link V1.0
UL approvalcULus Listed, General Purpose
Connection typeConnector plug M12 x 1 , 5-pin
CSA approvalcCSAus Listed, General Purpose
Switching frequency 2 Hz
Repeat accuracy 0.1 % of full-scale value
Interface typeIO-Link
Transducer frequencyapprox. 85 kHz
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Transfer rateAcyclical: typical 54 Bit/s
Dead band0 ... 200 mm
Output type2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected
Mass95 g
LED yellow 2solid: Object in evaluation range
flashing: Learning function, object detected
Sensing range200 ... 4000 mm
Degree of protectionIP67
LED yellow 1solid: Object in evaluation range
flashing: Learning function, object detected
Temperature influence 1.5 % from full-scale value (with temperature compensation)
0.2 %/K (without temperature compensation)
No-load supply current 60 mA
SIO mode supportyes
Voltage drop 2.5 V
Cycle timemin. 59.2 ms
LED greensolid: Power on
flashing: Standby mode or IO link communication

Comments

No comments yet