Pepperl+Fuchs UC500-30GM-E6R2-V15
Ultrasonic sensor

Pepperl+Fuchs UC500-30GM-E6R2-V15
We ship to United States of America!
  • Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 3000
  • 2 programmable switch outputs
  • Hysteresis mode selectable
  • Window mode selectable
  • Synchronization options
  • Adjustable acoustic power and sensitivity
  • Temperature compensation
Item Number: UC500-30GM-E6R2-V15
274.50
-
+
Total price: 274.50
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +
Switching frequency 7 Hz
Sensing range30 ... 500 mm
LED redsolid: temperature/program plug not connected
flashing: fault or program function object not detected
LED greensolid: Power-on
flashing: Standby mode or program function object detected
CCC approvalCCC approval / marking not required for products rated 36 V
CSA approvalcCSAus Listed, General Purpose
Rated operating current200 mA , short-circuit/overload protected
Operating voltage10 ... 30 V DC , ripple 10 %SS
Temperature influence 2 % from full-scale value (with temperature compensation)
0.2 %/K (without temperature compensation)
LED yellow 2solid: switching state switch output 2
flashing: program function
Connection typeConnector M12 x 1 , 5-pin
No-load supply current 50 mA
Interface typeRS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
Repeat accuracy 0.1 % of full-scale value
LED yellow 1solid: switching state switch output 1
flashing: program function
Adjustment range50 ... 500 mm
Voltage drop 2.5 V
Mass140 g
Ambient temperature-25 ... 70 ?°C (-13 ... 158 ?°F)
Range hysteresis1 % of the adjusted operating range (default settings), programmable
Transducer frequencyapprox. 380 kHz
Standard target plate100 mm x 100 mm
Degree of protectionIP65
Storage temperature-40 ... 85 ?°C (-40 ... 185 ?°F)
Response delay21 ms minimum
63 ms factory setting
UL approvalcULus Listed, General Purpose
Synchronizationbi-directional
0 level -UB...+1 V
1 level: +4 V...+UB
input impedance: > 12 KOhm
synchronization pulse: 100 micro/s, synchronization interpulse period: 2 ms
Dead band0 ... 30 mm
Output type2 switch outputs PNP, NO/NC, programmable
Temperature/TEACH-IN connectorTemperature compensation , Switch points programming , output function setting