Pepperl+Fuchs UC500-30GM-IUEP-IO-V15
Ultrasonic sensor

Pepperl+Fuchs UC500-30GM-IUEP-IO-V15
  • IO-link interface for service and process data
  • Programmable via DTM with PACTWARE
  • Switch output and analog output
  • Selectable sound lobe width
  • Synchronization options
  • Temperature compensation
Item Number: UC500-30GM-IUEP-IO-V15
355.24
-
+
Total price: 355.24
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Degree of protectionIP67
ProtocolIO-Link V1.0
Transducer frequencyapprox. 380 kHz
Output type1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected
Current output 4 mA ... 20 mA or
voltage output 0 V ... 10 V configurable
Connection typeConnector plug M12 x 1 , 5-pin
Dead band0 ... 30 mm
Repeat accuracy 0.1 % of full-scale value
Cycle timemin. 13.2 ms
Process data witdh16 bit
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
Operating voltage10 ... 30 V DC , ripple 10 %SS
15 ... 30 V voltage output
Range hysteresis1 % of the adjusted operating range (default settings), programmable
CSA approvalcCSAus Listed, General Purpose
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Sensing range30 ... 500 mm
Voltage drop 2.5 V
Response delayminimum : 25 ms
factory setting: 45 ms
No-load supply current 60 mA
CCC approvalCCC approval / marking not required for products rated 36 V
Power consumption 1 W
LED yellow 2solid: Object in evaluation range
flashing: Learning function, object detected
Resolutioncurrent output: evaluation range [mm]/3200 but andge;0.05 mm
voltage output: evaluation range [mm]/4000 but andge;0.05 mm
LED yellow 1solid: Object in evaluation range
flashing: Learning function, object detected
Temperature influence 1.5 % from full-scale value (with temperature compensation)
0.2 %/K (without temperature compensation)
Deviation of the characteristic curve 0.2 % of full-scale value
UL approvalcULus Listed, General Purpose
Load impedancecurrent output: 300 Ohm
voltage output: 1000 Ohm
Standard target plate100 mm x 100 mm
LED greensolid: Power on
flashing: Standby mode or IO link communication
Interface typeIO-Link
Input/output type1 synchronization connection, bidirectional
Mass66 g
Rated operating current200 mA , short-circuit/overload protected
SIO mode supportyes
Transfer rateAcyclical: typical 240 Bit/s
Adjustment range50 ... 500 mm
Switching frequency 11 Hz
LED redsolid red: Error
red, flashing: program function, object not detected

Comments

No comments yet