Pepperl+Fuchs VAA-2E-KE1-S
AS-Interface safety module

Pepperl+Fuchs VAA-2E-KE1-S
We ship to United States of America!
  • 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch
  • Housing with removable terminals
  • Communication monitoring
  • Power supply of inputs from the module
  • Function display for bus and inputs
  • Cross-circuit detection
  • Addressing jack
Item Number: VAA-2E-KE1-S
123.37
-
+
Total price: 123.37
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
  • Overview +
  • Comments +
Rated operating voltage26.5 ... 31.6 V PELV from AS-Interface
Storage temperature-25 ... 85 ?°C (-13 ... 185 ?°F)
LED FAULTerror display; LED red
red: communication error or address is 0
Shock and impact resistance10 g, 16 ms in 6 spatial directions 1000 shocks
Safety Integrity Level (SIL)SIL 3
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
AS-InterfaceEN 62026-2:2013
MTTFd200 a
IO code0
Voltage20 ... 30 V DC pulsed
ID codeB
Parameter bits (programmable via AS-i)function
LED INswitching state (input); 2 LED yellow
Emitted interferenceEN 61000-6-4:2001
Ambient temperature-25 ... 50 ?°C (-13 ... 122 ?°F)
Data bits (function via AS-Interface) input output
Rated operating current 70 mA
Connectionremovable terminals, terminal connection 2.5 mm2
Degree of protectionEN 60529:2000
Mass80 g
Electromagnetic compatibilityEN 61000-6-2, EN 61000-4-5 1 kV asymmetric, criterion B, EN 61000-6-4
AS-Interface specificationV2.1
ID2 code0
LED PWRAS-Interface voltage; LED green
ID1 codeF
Slave typeSafety-Slave
Supplyfrom AS-Interface
Degree of protectionIP20
MountingDIN mounting rail
Current loading capacityinput current limited 15 mA,
overload and short-circuit resistant
Electrical safetyEN 50178:1998 IEC 60204-1:2007
ProfileS-0.B
Fieldbus standardEN 62026-2:2013
StandardsNFPA 79:2002
Required master specification V2.0
Number/Type2 safety-related inputs for mechanical contacts, cross-circuit monitored:
2 single-channel contacts: up to category 2 in accordance with EN 954-1 or
1, 2-channel contact: up to category 4 in accordance with EN 954-1
Cable length must not exceed 300 m per input.
Functional safetyEN 954-1:1996 (up to category 4), BIA Final Draft ""Proposal for a principle to the verification and certification of field busses for transmission of safety related signals"" 28.05.2000, IEC 61508 up to SIL3
Insulation coordinationEN 50178:1998
UL File NumberE87056
Protection classIII

Buy Pepperl+Fuchs VAA-2E-KE1-S with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a fast-developing company in supplying industrial automation devices. Thanks to our wide range of products, you won't need other suppliers. We ship to any country in the world. We have low prices and always deliver on time. You can receive daily support from your personal manager. Availability, efficiency, and flexibility are our main principles.