Pepperl+Fuchs VAA-2E2A-KE1-S/E2
AS-Interface safety module

Pepperl+Fuchs VAA-2E2A-KE1-S/E2
  • 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch
  • Housing with removable terminals
  • Communication monitoring
  • Power supply of outputs from the external auxiliary voltage
  • Power supply of inputs from the module
  • Function display for bus, ext. auxiliary voltage, inputs and outputs
  • Output overload monitoring
  • Switchable internal logic operation of the inputs and outputs via parameter bit
  • Addressing jack
Item Number: VAA-2E2A-KE1-S/E2
186.34
-
+
Total price: 186.34
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Relative humidity85 % , noncondensing
Ambient temperature-25 ... 50 В°C (-13 ... 122 В°F)
LED OUTSwitching state (output); 2 LED yellow
Safety Integrity Level (SIL)SIL 3
Parameter bits (programmable via AS-i)function
LED INswitching state (input); 2 LED yellow
Supplyfrom external auxiliary voltage UAUX
Slave typeSafety-Slave
AS-InterfaceEN 62026-2:2013
ID codeB
MountingDIN mounting rail
Emitted interferenceEN 61000-6-4:2001
AS-Interface specificationV2.1
LED AUXext. auxiliary voltage UAUX ; LED green
StandardsNFPA 79:2002
Electrical safetyEN 50178:1998 IEC 60204-1:2007
LED PWRAS-Interface voltage; LED green
Rated operating voltage26.5 ... 31.6 V from AS-Interface
ID2 code0
Supplyfrom AS-Interface
Climatic conditionsFor indoor use only
Connectionremovable terminals, terminal connection 2.5 mm2
Auxiliary voltage (output)20 ... 30 V DC PELV
Performance level (PL)PL e
Degree of protectionEN 60529:2000
Surge protectionUAUX, Ue: overvoltage category II, safe isolated power supplies (PELV)
Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-4-5:2005 1 kV asymmetric, criterion B, EN 61000-6-4:2007
Pollution degree2
MTTFd200 a
Required master specification V2.1
Current loading capacityinput current limited 15 mA,
overload and short-circuit resistant
Voltage (UAUX - 0.5 V)
Current0.5 A per output
Shock and impact resistance10 g, 16 ms in 6 spatial directions 1000 shocks
PFD0
Voltage20 ... 30 V DC pulsed
Number/Type2 safety-related inputs for mechanical contacts, cross-circuit monitored:
2 single-channel contacts: up to category 2 in accordance with EN 954-1 or
1, 2-channel contact: up to category 4 in accordance with EN 954-1
Cable length must not exceed 300 m per input.
UL File NumberE223772
Rated operating current 70 mA
PFHd0
ID1 codeF
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Data bits (function via AS-Interface) input output
IO code7
Insulation coordinationEN 50178:1998
ProfileS-7.B
Number/Type2 conventional electronic outputs, PNP
Altitude 2000 m above MSL
Degree of protectionIP20
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Mass80 g
Fieldbus standardEN 62026-2:2013
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm
Protection classIII
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: Output supply overload
Functional safetyEN ISO 13849-1:2006 up to PL e, IEC 61508:2009 up to SIL 3

Comments

No comments yet