Pepperl+Fuchs VAA-2E2A-KE1-SE
AS-Interface safety module

Pepperl+Fuchs VAA-2E2A-KE1-SE
  • Two inputs for connecting a noncontact safety device (opto-electronic safety device) PL e in accordance with EN ISO 13849-1
  • Inputs for photoelectric protective systems
  • Housing with removable terminals
  • Power supply of the inputs from the AUX auxiliary voltage
  • Power supply of outputs from auxiliary voltage AUX
  • Function display for bus, auxiliary voltage AUX, inputs and outputs
  • Up to SIL3 (EN 62061) and PLe (EN13849-1)
Item Number: VAA-2E2A-KE1-SE
153.51
-
+
Total price: 153.51
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Safety Integrity Level (SIL)SIL 3
Rated operating voltage22 ... 31.6 V
Required master specification V2.1
Voltage20 ... 30 V DC pulsed
LED INswitching state (input); 2 LED yellow
Current1 A per output
Note derating
Storage temperature-40 ... 85 В°C (-40 ... 185 В°F)
PFD8 E-7
Supplyfrom AUX
Connectionremovable terminals, terminal connection 0.2 ... 2.5 mm2
Mission Time (TM)20 a
Current consumptionmax. 35 mA (AS-Interface)
max. 4 A (AUX)
Ambient temperature0 ... 55 В°C (32 ... 131 В°F) , no moisture condensation
MountingDIN mounting rail
Degree of protectionIP20
Number/Type2 inputs for a 2-channel active optoelectronic protective devices (AOPD) for safeguarding positions and areas of danger up to PL e in accordance with EN / ISO 13849-1
Data bits (function via AS-Interface) input output
Rated operating current 70 mA
PFHd2.83 E-9
ProfileS-7.B.1.
ID codeB
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm
Number/Type2 conventional electronic outputs, short-circuit proof
Current loading capacity1800 mA for power supply of external sensors from AUX
LED OUTSwitching state (output); 2 LED yellow
LED FAULTFault indication: red LED
Red: communication error or address is 0
Red flashing: peripheral fault
IO code7
Altitude 2000 m above MSL
Mass60 g
Auxiliary voltage (output)24 V (20 VDCandhellip; 30 VDC)
LED AS-iAS-Interface voltage; LED green
ID2 code1
Parameter bits (programmable via AS-i)function
Performance level (PL)PL e
Protection classIII
ID1 codeF
Supplyfrom AUX
Slave typeSafety-Slave
Switching pointVin> 11 V for high level, input current 2.5 mA at 15 V
UL File NumberE223772
LED AUXauxiliary voltage UAUX ; LED green
Surge protectionUAUX, Ue: overvoltage category II, safe isolated power supplies (PELV)
AS-Interface specificationV3.0

Comments

No comments yet

Write a comment