Pepperl+Fuchs VAA-2E2A-KE1P-S/E2
AS-Interface safety module

Pepperl+Fuchs VAA-2E2A-KE1P-S/E2
We ship to United States of America!
  • 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch
  • Housing with removable terminals
  • Communication monitoring
  • Power supply of outputs from the external auxiliary voltage
  • Power supply of inputs from the module
  • Function display for bus, ext. auxiliary voltage, inputs and outputs
  • Output overload monitoring
  • Switchable internal logic operation of the inputs and outputs via parameter bit
  • Addressing jack
Item Number: VAA-2E2A-KE1P-S/E2
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
Data bits (function via AS-Interface) input output
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm
Insulation coordinationEN 50178:1998
Auxiliary voltage (output)20 ... 30 V DC PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
PFD0
LED AUXext. auxiliary voltage UAUX ; LED green
MountingDIN mounting rail
Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-4-5:2005 1 kV asymmetric, criterion B, EN 61000-6-4:2007
Current loading capacityinput current limited ≤ 15 mA,
overload and short-circuit resistant
Voltage≥ (UAUX - 0.5 V)
ID1 codeF
Supplyfrom AS-Interface
Required master specification≥ V2.1
Altitude≤ 2000 m above MSL
Current0.5 A per output
LED INswitching state (input); 2 LED yellow
Voltage20 ... 30 V DC pulsed
AS-InterfaceEN 62026-2:2013
Climatic conditionsFor indoor use only
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Shock and impact resistance10 g, 16 ms in 6 spatial directions 1000 shocks
Surge protectionUAUX, Ue: overvoltage category II, safe isolated power supplies (PELV)
Pollution degree2
Electrical safetyEN 50178:1998 IEC 60204-1:2007
IO code7
Performance level (PL)PL e
PFHd0
ID codeB
LED OUTSwitching state (output); 2 LED yellow
Mass80 g
Degree of protectionIP20
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: Output supply overload
Number/Type2 conventional electronic outputs, PNP
UL File NumberE223772
Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored:
2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or
1 2-channel contact: up to category 4/PL e to ISO 13849-1
Cable length must not exceed 300 m per input.
Relative humidity85 % , noncondensing
ID2 code0
Emitted interferenceEN 61000-6-4:2007
Connectionremovable spring terminals
Conductor cross-section 0,25 ... 2,5 mm2
Parameter bits (programmable via AS-i)function
Slave typeSafety-Slave
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
ProfileS-7.B
Supplyfrom external auxiliary voltage UAUX
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
Safety Integrity Level (SIL)SIL 3
AS-Interface specificationV2.1
Ambient temperature-25 ... 50 В°C (-13 ... 122 В°F)
MTTFd200 a
Rated operating current≤ 70 mA
Functional safetyEN ISO 13849-1:2015 up to PL e, IEC 61508:2010 and IEC 62061:2005/A2:2015 up to SIL 3
LED PWRAS-Interface voltage; LED green
Protection classIII
StandardsNFPA 79:2002

Buy Pepperl+Fuchs VAA-2E2A-KE1P-S/E2 with the best possible price and delivery terms on eltra-trade.com

eltra-trade.com is your reliable source for industrial electrical parts. Our extensive product range includes various automation equipment, all available for fast delivery. We guarantee quality and competitive prices. Make us your preferred partner for all your electrical supply needs.

Comments

No comments yet

Write a comment