Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral
Slave typeStandard slave
Auxiliary voltage (output)24 V DC В± 15 % PELV
ID2 codeE
Mass200 g
Noise immunityEN 61000-6-2:2005
Tightening torque, cable gland0.4 Nm
ProfileS-8.1
Required master specification V2.1
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Emitted interferenceEN 61000-6-4:2007
Relative humidity85 % , noncondensing
ID1 codeF
Mission Time (TM)20 a
Rated operating voltage26.5 ... 31.6 V from AS-Interface
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
UL File NumberE223772
MountingMounting plate
Degree of protectionEN 60529:2000
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: Output supply overload
LED PWRAS-Interface voltage; green LED
green: voltage OK
flashing green: address 0
ConnectionCable piercing method
flat cable yellow/flat cable black
inputs/outputs: M12 round connector
LED OUTSwitching status (output); 4 yellow/red LEDs
Yellow: output active
Red: output overload
MTTFd230 a
IO code8
ID code1
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks
10 g, 16 ms in 6 spatial directions 1000 shocks
Fieldbus standardEN 62026-2:2013
Number/Type4 electronic outputs, PNP
Data bits (function via AS-Interface) input output
Parameter bits (programmable via AS-i)function
Rated operating current 40 mA
Diagnostic Coverage (DC)0 %
AS-Interface specificationV3.0
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Degree of protectionIP67
Climatic conditionsFor indoor use only
AS-InterfaceEN 62026-2:2013
Current2 A per output
6 A total (TB 40 В°C)
4 A total (TB 70 В°C)
Altitude 2000 m above MSL
Pollution degree3
Supplyfrom external auxiliary voltage UAUX
Voltage (UAUX - 0.5 V)
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Protection classIII