Pepperl+Fuchs VAA-4E4A-CB-ZE/E2-Y129640 AS-Interface printed circuit board module


Item Number: VAA-4E4A-CB-ZE/E2-Y129640
- Integrated communication monitoring function
- Inputs and outputs short-circuit and overload proof
- Connection via Card-Edge plug connector (AMP 145432-2)
- Power supply of outputs from the external auxiliary voltage
- Inputs are galvanically separated from each other
- Detection of output overload
- Function display for bus, ext. auxiliary voltage, inputs and outputs
- Addressing jack
- Overview
- Datasheet
- Alternative numbers
- Comments
Auxiliary voltage (output) | 20 ... 30 V DC PELV |
Supply | from external auxiliary voltage UEXT |
IO code | 7 |
Dimensions | 65.7 mm x 40 mm x 8 mm |
Profile | S-7.0 |
LED IN | switching state (input); 4 LED yellow |
Ambient temperature | -25 ... 60 В°C (-13 ... 140 В°F) |
ID1 code | F |
Connection | Card edge connector, type AMP 145432-2 |
LED OUT | Switching state (output); 4 LED yellow |
AS-Interface specification | V2.1 |
Rated operating current | ≤ 40 mA |
LED FAULT | error display; LED red red: communication error or address is 0 red flashing: overload of outputs |
Degree of protection | EN 60529:2000 |
AS-Interface | EN 62026-2:2013 |
Current | ≤ 700 mA per output |
Data bits (function via AS-Interface) | |
Protection class | III |
Input current | ≤ 8 mA (limited internally) |
ID2 code | E |
LED PWR | AS-Interface voltage; LED green |
LED AUX | ext. auxiliary voltage UAUX ; LED green |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Number/Type | 4 electronic outputs, PNP |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
Parameter bits (programmable via AS-i) | function |
Auxiliary voltage (input) | 20 ... 30 V DC PELV |
Mass | approx. 13 g |
ID code | 0 |
Supply | from external auxiliary voltage UAUX |
Switching point | according to EN 61131-2 Type 2 |
Slave type | Standard slave |