Pepperl+Fuchs VAA-4E4A-G11-ZAJ/EA2L-F
AS-Interface sensor/actuator module
We ship to United States of America!
- Inputs for 2-, 3-, and 4-wire sensors
- Power supply of outputs from the external auxiliary voltage
- Supply of sensors from AS-Interface
- Function display for bus, external auxiliary voltage, in- and outputs
- Red LED per channel, lights up in the event of output overload
- Communication monitoring
- Switchable lead breakage detection (outputs)
- Cable piercing method with gold plated contact pins
- Degree of protection IP68 / IP69K
- AS-Interface POWER24
Item Number:
VAA-4E4A-G11-ZAJ/EA2L-F
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
- Overview +
- Comments +
Output/AS-Interface | safe isolation, rated insulation voltage 40 V DC |
Tightening torque, housing screws | 1.8 Nm |
Ambient temperature | -25 ... 70 ?°C (-13 ... 158 ?°F) |
Degree of protection | IP68 / IP69K |
Altitude | 2000 m above MSL |
ID1 code | F |
Auxiliary voltage (output) | 20 ... 30 V DC PELV |
Signal delay | < 1 ms (input/AS-Interface) |
Current | 2 A per output TB 40 ?°C: 6 A total TB 70 ?‚?°C: sum O1 + O2 max. 2 A, sum O3 + O4 max. 2 A |
LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
Input current | 9 mA (limited internally) |
Degree of protection | EN 60529:2000 |
Emitted interference | EN 61000-6-4:2007 |
Rated operating current | 40 mA (without sensors) / max. 240 mA |
Pollution degree | 3 |
Parameter bits (programmable via AS-i) | function |
Input/Output | safe isolation, rated insulation voltage 40 V DC |
Connection | AS-Interface/UAUX: AS-Interface flat cable Inputs/outputs: M12 round connector |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC |
UL File Number | E223772 |
AS-Interface | EN 62026-2:2013 |
Supply | from external auxiliary voltage UAUX |
Climatic conditions | For indoor use only |
Voltage | (UAUX - 0.5 V) |
Fieldbus standard | EN 62026-2:2013 |
ID code | F |
Input | EN 61131-2:2007 |
Rated operating voltage | 18,0 ... 31.6 V from AS-Interface |
Profile | S-7.F |
LED OUT | switching state (output); 4 LED yellow/red yellow: output active red: output overload or lead interruption |
Mounting | Mounting plate |
Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
ID2 code | E |
Voltage | 12 ... 31 V |
Supply | from AS-Interface |
IO code | 7 |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Switching point | according to DIN EN 61131-2 (Type 2) |
Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
Storage temperature | -25 ... 85 ?°C (-13 ... 185 ?°F) |
AS-Interface specification | V3.0 |
Slave type | Standard slave |
Protection class | III |
Mass | 200 g |
Data bits (function via AS-Interface) | |
LED IN | switching state (input); 4 LED yellow |
Current loading capacity | 200 mA, overload and short-circuit protected |
LED AS-i/FAULT | Status display; multi-colour LED Green: normal operation Red: communication fault Flashing yellow/red: address 0 Flashing green/red: sensor supply i.e. overload or lead interruption outputs |
Tightening torque, cable gland | 0.4 Nm |
Required master specification | V2.1 |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks |
Relative humidity | 85 % , noncondensing |
Buy Pepperl+Fuchs VAA-4E4A-G11-ZAJ/EA2L-F with the best possible price and delivery terms on eltra-trade.com
You will find a lot of industrial electrical products on eltra-trade.com. We have the status of the official representative of many European brands. We deliver to any country in the world. Our company is not an official distributor of all brands, but we can offer you competitive prices for all items in our catalog. We provide accurate delivery time information at the very beginning. We are the partner who can trust.