Pepperl+Fuchs VAA-4E4A-G20-ZEJ/M2L-P7-GEB
AS-Interface I/O module

Pepperl+Fuchs VAA-4E4A-G20-ZEJ/M2L-P7-GEB
  • Inputs for 3-wire sensors
  • Outputs for DC roller motors (drum motors)
  • Connection of motors and sensors via M8 connectors
  • Configurable starting ramp
  • Communication monitoring
  • Supply for inputs from AS-Interface
  • Power supply of outputs from the external auxiliary voltage
  • Function display for bus, external auxiliary voltage, in- and outputs
  • Cable piercing method with gold plated contact pins
Item Number: VAA-4E4A-G20-ZEJ/M2L-P7-GEB
259.78
-
+
Total price: 259.78
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Cable length0.5 m
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Climatic conditionsFor indoor use only
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Altitude 2000 m above MSL
LED FUSEMotor power supply; 2 green LEDs
Mass250 g
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Input filter2 ms
Mounting2 clips with andempty; 8 mm drill hole
Number/Type2 outputs for DC roller motors (MOT1, MOT2)
Number/Type4 Inputs for 3-wire sensors (PNP), DC
Degree of protectionIP54 according to EN 60529
Slave typeStandard slave
Supplyfrom external auxiliary voltage UAUX
Input current 6 mA (internally limited)
LED DIRMotor rotation direction; yellow LED
Rotation direction signalPNP digital output
low: high impedance
high; (VAUX - 2.5 V) in no-load operation
Switching pointaccording to DIN EN 61131-2
0 (undamped) 0.5 mA
1 (damped) 2.0 mA
AS-InterfaceEN 62026-2:2013
LED INswitching state (input); 4 LED yellow
InputEN 61131-2:2007
Required master specification V2.1
NoteThe flat cable routing is designed for 100 actuation cycles
Signal delay< 1 ms (input/AS-Interface)
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
Overload protectionfuse , I2t = 53.7 A2s
ConnectionAS-Interface, AUX: Insulation piercing technology
Yellow flat cable/black flat cable
Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104
Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)
Matching connector: LM004-Gx1-A or similar
Outputs: LF005-GS1-B (5-pin, bushing contacts, screw lock, B-coded)
Matching connector: LM005-Gx1-B or similar
Degree of protectionEN 60529:2000
LED PWRAS-Interface voltage; green LED
green: voltage OK
green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing
Rated operating current 25 mA (without sensors) / max. 170 mA
MTBF98 a
Motor start signalPNP digital output
low: high impedance
high; (VAUX - 2.5 V) in no-load operation
Pollution degree2
ID2 codeE
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Relative humidity85 % non-condensing
Auxiliary voltage (output)18 ... 30 VDC PELV
ProfileS-7.0
UL File NumberE223772 ""For use in NFPA 79 Applications only""
Supplyfrom AS-Interface
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks
Vibration resistance0.35 mm / 2 g 10 ... 1000 Hz
ID code0
Data bits (function via AS-Interface) input output
Current loading capacity100 mA , overload and short-circuit protected
IO code7
AS-Interface specificationV3.0
Current2 A , max. 5 A (<2 s) per motor
Fieldbus standardEN 62026-2:2013
LED MOTMotor active; 2 yellow LEDs
ID1 codeF
Velocity signal0 ... 10 V DC
Control via parameter P2:0

Comments

No comments yet

Write a comment