Pepperl+Fuchs VAA-4E4A-G4-ZE/E2
AS-Interface sensor/actuator module

Pepperl+Fuchs VAA-4E4A-G4-ZE/E2
  • Degree of protection IP65
  • Flat or round cable connection (via standardized EEMS base, not included with delivery)
  • Cable piercing method for flat cable
  • Communication monitoring, turn-off
  • Inputs for 2- and 3-wire sensors
  • Power supply of outputs from the external auxiliary voltage
  • Power supply of inputs from the module
  • Function display for bus, ext. auxiliary voltage, inputs and outputs
  • Monitoring of sensor overloads
Item Number: VAA-4E4A-G4-ZE/E2
229.68
-
+
Total price: 229.68
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Current1 A per output, 4 A total
Voltage (UAUX - 0.5 V)
Degree of protectionEN 60529:2000
Slave typeStandard slave
Parameter bits (programmable via AS-i)function
Altitude 2000 m above MSL
Ambient temperature-25 ... 60 В°C (-13 ... 140 В°F)
Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Switching pointaccording to DIN EN 61131-2 (Type 2)
Relative humidity85 % , noncondensing
Pollution degree3
Voltage21 ... 31 V
AS-InterfaceEN 62026-2:2013
Protection classIII
IO code7
UL File NumberE223772
Mission Time (TM)20 a
Auxiliary voltage (output)24 V DC В± 15 % PELV
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
MTTFd150 a
InputEN 61131-2:2007
Data bits (function via AS-Interface) input output
Tightening torque, housing screws0.8 Nm
Climatic conditionsFor indoor use only
ID1 codeF
Diagnostic Coverage (DC)0 %
Input current 9 mA (limited internally)
ID2 codeE
LED PWR/FAULTdual LED green/red
green: AS-Interface voltage
red: communication error or address 0
green/red flashing: overload sensor supply or outputs
Mass350 g
Supplyfrom external auxiliary voltage UAUX
AS-Interface specificationV3.0
Fieldbus standardEN 62026-2:2013
Noise immunityEN 61000-6-2:2005 EN 62026-2:2013
LED OUTSwitching state (output); 4 LED yellow
Connectioncable piercing method or terminal compartment
yellow flat cable/black flat cable or standard round cable
inputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals
LED INswitching state (input); 4 LED yellow
LED AUXext. auxiliary voltage UAUX ; LED green
Supplyfrom AS-Interface
Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV)
Current loading capacity 200 mA (TB 40 В°C),
160 mA (TB 60 В°C), short-circuit protected
ProfileS-7.0
Number/Type4 electronic outputs, PNP, overload and short-circuit proof
MountingDIN rail or screw mounting
Emitted interferenceEN 61000-6-4:2007
Required master specification V2.0
Rated operating current 30 mA (without sensors) / max. 230 mA
ID code0
Degree of protectionIP65

Comments