Pepperl+Fuchs VAA-4E4A-KE-ZEJQ/E2L
AS-Interface sensor/actuator module

Pepperl+Fuchs VAA-4E4A-KE-ZEJQ/E2L
We ship to United States of America!
  • Housing with removable, mechanical and color coded terminals
  • Communication monitoring
  • Inputs for 2- and 3-wire sensors
  • Addressing jack
  • Power supply of outputs from the external auxiliary voltage
  • Selectable supply to the sensors: External or from the module
  • Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs
  • Red LED per channel, lights up in the event of output overload
  • Switchable lead breakage detection (outputs)
Item Number: VAA-4E4A-KE-ZEJQ/E2L
182.34
-
+
Total price: 182.34
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Auxiliary voltage (output)20 ... 30 V DC PELV
Switching pointaccording to DIN EN 61131-2 (Type 2)
AS-Interface specificationV3.0
UL File NumberE223772
Supplyfrom external auxiliary voltage UAUX
ID code0
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Fieldbus standardEN 62026-2:2013
Diagnostic Coverage (DC)0 %
Parameter bits (programmable via AS-i)function
Surge protectionUEXT, UAUX, Ue: Over voltage category III, safe isolated power supplies (PELV)
ID1 codeF
Input current 9 mA (limited internally)
Data bits (function via AS-Interface) input output
Emitted interferenceEN 61000-6-4:2007
Rated operating current 35 mA (without sensors) / max. 190 mA
Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Required master specification V2.0
Connectionremovable terminals
rated connection capacity:
rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-section:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Ambient temperature-25 ... 60 В°C (-13 ... 140 В°F)
LED FAULTError display; red LED
red: communication error, i.e. address is 0
red flashing: overload internal input supply, i.e. overload or lead interruption outputs
Usage categoryDC-13
Current2 A per output, sum 4A (TB 40 В°C)
0.5 A per output, total 2A (TB 60 В°C, arranged in series without gaps)
2 A per output, total 4A (TB 60 В°C, arranged in series with 5 mm gap)
Mass150 g
LED INswitching state (input); 4 LED yellow
Mission Time (TM)20 a
Slave typeStandard slave
Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT)
LED INTInternal input supply active; LED green
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm
Degree of protectionIP20
AS-InterfaceEN 62026-2:2013
Altitude 2000 m above MSL
Pollution degree2
LED OUTswitching state (output); 4 LED yellow/red
yellow: output active
red: output overload or lead interruption
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Number/Type4 electronic outputs, PNP, overload and short-circuit proof
ProfileS-7.0
Climatic conditionsFor indoor use only
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Protection classIII
Signal delay< 1 ms (input/AS-Interface)
Voltage21 ... 31 V DC (INT)
InputEN 61131-2:2004
LED PWRAS-Interface voltage; green LED
green: voltage OK
flashing green: address 0
Degree of protectionEN 60529:2000
Current loading capacity 150 mA, overload- and short-circuit protected (INT)
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
Voltage (UAUX - 0.5 V)
Auxiliary voltage (input)12 ... 30 V DC PELV
IO code7
Relative humidity85 % , noncondensing
MTTFd190 a
MountingDIN mounting rail
ID2 codeE