Pepperl+Fuchs VAA-4E4A-KE-ZEJQ/E2L
AS-Interface sensor/actuator module
- Housing with removable, mechanical and color coded terminals
- Communication monitoring
- Inputs for 2- and 3-wire sensors
- Addressing jack
- Power supply of outputs from the external auxiliary voltage
- Selectable supply to the sensors: External or from the module
- Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs
- Red LED per channel, lights up in the event of output overload
- Switchable lead breakage detection (outputs)
Item Number:
VAA-4E4A-KE-ZEJQ/E2L
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Auxiliary voltage (output) | 20 ... 30 V DC PELV |
Switching point | according to DIN EN 61131-2 (Type 2) |
AS-Interface specification | V3.0 |
UL File Number | E223772 |
Supply | from external auxiliary voltage UAUX |
ID code | 0 |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Fieldbus standard | EN 62026-2:2013 |
Diagnostic Coverage (DC) | 0 % |
Parameter bits (programmable via AS-i) | function |
Surge protection | UEXT, UAUX, Ue: Over voltage category III, safe isolated power supplies (PELV) |
ID1 code | F |
Input current | 9 mA (limited internally) |
Data bits (function via AS-Interface) | |
Emitted interference | EN 61000-6-4:2007 |
Rated operating current | 35 mA (without sensors) / max. 190 mA |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
Required master specification | V2.0 |
Connection | removable terminals rated connection capacity: rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2 for multiple-wire connection with two wires of equal cross-section: flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
Ambient temperature | -25 ... 60 В°C (-13 ... 140 В°F) |
LED FAULT | Error display; red LED red: communication error, i.e. address is 0 red flashing: overload internal input supply, i.e. overload or lead interruption outputs |
Usage category | DC-13 |
Current | 2 A per output, sum 4A (TB 40 В°C) 0.5 A per output, total 2A (TB 60 В°C, arranged in series without gaps) 2 A per output, total 4A (TB 60 В°C, arranged in series with 5 mm gap) |
Mass | 150 g |
LED IN | switching state (input); 4 LED yellow |
Mission Time (TM) | 20 a |
Slave type | Standard slave |
Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
LED INT | Internal input supply active; LED green |
Tightening torque of clamping screws | 0.5 Nm ... 0.6 Nm |
Degree of protection | IP20 |
AS-Interface | EN 62026-2:2013 |
Altitude | 2000 m above MSL |
Pollution degree | 2 |
LED OUT | switching state (output); 4 LED yellow/red yellow: output active red: output overload or lead interruption |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
Profile | S-7.0 |
Climatic conditions | For indoor use only |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Protection class | III |
Signal delay | < 1 ms (input/AS-Interface) |
Voltage | 21 ... 31 V DC (INT) |
Input | EN 61131-2:2004 |
LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
Degree of protection | EN 60529:2000 |
Current loading capacity | 150 mA, overload- and short-circuit protected (INT) |
LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
Voltage | (UAUX - 0.5 V) |
Auxiliary voltage (input) | 12 ... 30 V DC PELV |
IO code | 7 |
Relative humidity | 85 % , noncondensing |
MTTFd | 190 a |
Mounting | DIN mounting rail |
ID2 code | E |