Pepperl+Fuchs VAA-4E4A-KE5-ZEJQ/R
AS-Interface sensor/actuator module

Pepperl+Fuchs VAA-4E4A-KE5-ZEJQ/R
We ship to United States of America!
  • Housing with push-in connection technology and mechanically coded terminal blocks
  • Housing width 19 mm, installation in the switch cabinet on DIN mounting rail
  • Selectable supply to the sensors: External or from the module
  • Function display for bus, internal sensor supply, inputs, and outputs
Item Number: VAA-4E4A-KE5-ZEJQ/R
179.38
-
+
Total price: 179.38
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
LED INTInternal input supply active; LED green
Relative humidity85 % , noncondensing
Output/OutputBasic insulation, rated insulation voltage 250 Veff, in phase
ID2 codeE
Input/AS-InterfaceSwitch position INT: None Switch setting EXT: safe isolation, rated insulation voltage 92 Veff
MTBF224 a
Voltage21 ... 31 V DC (INT)
Required master specification V2.0
ConnectionRemovable push-in terminals
rated connection capacity:
rigid: 0.20 mm2 ... 1.5 mm2
flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2
flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026:2013
Signal delay< 1 ms (input/AS-Interface)
Altitude 2000 m above MSL
Number/Type4 relay outputs, normally open
ProfileS-7.0
AS-InterfaceEN 62026-2:2013
Auxiliary voltage (input)12 ... 30 V DC PELV
Switching delay< 10 ms (AS-Interface/contact)
Number/Type4 inputs for 3-wire sensors (PNP), DC
Slave typeStandard slave
Switching pointaccording to DIN EN 61131-2 (type 1)
Parameter bits (programmable via AS-i)function
LED OUTSwitching state (output); 4 LED yellow
Emitted interferenceEN 61000-6-4:2007
LED PWRAS-Interface voltage; green LED
green: voltage OK
flashing green: address 0
Input current 5.6 mA (max.)
Mass125 g
MountingDIN mounting rail
Fieldbus standardEN 62026-2:2013
Vibration resistance0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Output/AS-Interfacesafe isolation, Rated insulation voltage 252 Veff
Electrical safetyIEC 61140:2009
Pollution degree2
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Degree of protectionEN 60529:2000
Ambient temperature-25 ... 60 В°C (-13 ... 140 В°F)
IO code7
Usage categoryDC-13 and AC-14
AS-Interface specificationV3.0
Input/Outputsafe isolation, Rated insulation voltage 252 Veff
Supplynone
Data bits (function via AS-Interface) input output
Rated operating current 35 mA (without sensors) / max. 230 mA
UL File NumberE223772
Control circuit 11 mA per relay (from AS-Interface)
Current loading capacity 150 mA, overload- and short-circuit protected (INT)
Degree of protectionIP20
Installation in an enclosure with a minimum protection class of IP54 required
LED FAULTFault display; Red LED
red: Communication fault or address is 0
red, flashing: Overload, internal input supply
ID1 codeF
Climatic conditionsFor indoor use only
Shock and impact resistance15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks
ID code0
LED INswitching state (input); 4 LED yellow
Surge protectionO1 ... O4: Over voltage category II
UEXT, Ue: overvoltage category II, safe isolated power supplies (PELV)
Galvanic isolationEN 60664-1:2007
InputEN 61131-2:2004
Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT)

Buy Pepperl+Fuchs VAA-4E4A-KE5-ZEJQ/R with the best possible price and delivery terms on eltra-trade.com

Eltra Trade s.r.o. is a leading online electrical distributor. Our catalog features a vast selection of automation products from top brands. We deliver worldwide, offering competitive prices and timely shipments. Let us help you streamline your supply chain and improve your business efficiency.

Comments

No comments yet

Write a comment