Pepperl+Fuchs VAZ-2E2A-G20-ZPA1
Stand-alone connecting module

- Inputs for 3-wire sensors
- Outputs for DC roller motors (drum motors)
- Interface for coupling with adjacent zones
- Connection of motors and sensors via M8 connectors
- Operating mode, motor speed and start/stop ramp can be configured using the rotary switch
- Supply of 24 VDC, connection via insulation piercing technology with gold-plated contact pins
- Function indicator for power supply, inputs and outputs, and zone coupling

Item Number:
VAZ-2E2A-G20-ZPA1
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Datasheet
- Alternative numbers
- Comments
Altitude | ≤ 2000 m above MSL |
Connection | PWR: insulation piercing technology Black flat cable Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104 Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded) Matching connector: LM004-Gx1-A or similar Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded) Matching connector: NM005-Sx1-B or similar Zone coupling: M12 round plug connector in accordance with EN 61076-2-101 X1: M12, 4-pin, bushing contacts, screw-locking, A-coded Female connector: M12, 4-pin, connector contacts, screw-locking, A-coded X2: M12, 4-pin, connector contacts, screw-locking, A-coded Female connector: M12, 4-pin, bushing contacts, screw-locking, A-coded |
Switching point | in accordance with DIN EN 61131-2 (type 1) 0 (undamped): ≤ 0.5 mA 1 (damped): ≥ 2 mA |
Interface type | Interface for coupling zones with one input and one output for control signals X1 |
Velocity signal | 1.4 … 13 V at no-load Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ Control using rotary switch S1 |
LED XOUT | Zone coupling output active; 2 yellow LEDs |
Switching point | according to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA 1 (damped) ≥ 2.0 mA |
Supply | via UPWR |
Input | EN 61131-2:2007 |
Mass | 310 g |
Noise immunity | EN 61000-6-2:2005 , EN 61326-1:2006 |
Degree of protection | EN 60529:2000 |
Surge protection | UPWR: overvoltage category II, securely isolated power supply (PELV) |
Pollution degree | 2 |
Physical | 4-pin M12 socket Electronic output: PNP, overload and short-circuit proof (X1OUT) Input: PNP, galvanically isolated, potential-free (X1IN) |
Cable length | 1 m (inputs/outputs) , 1.5 m (zone coupling), max. 30 m |
Relative humidity | 85 % non-condensing |
Voltage | Input: max. 30 V DC Output (via UPWR): ≥ (UPWR - 2 V) |
Overload protection | fuse , I2t = 53.7 A2s |
Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
Number/Type | 2 outputs for DC roller motors (MOT1, MOT2) |
Current | 2 A , max. 5 A (<2 s) per motor |
Mounting | 2 clips with ∅ 8 mm drill hole |
Number/Type | 2 Inputs for 3-wire sensors (PNP), DC |
Interface type | Interface for coupling zones with one input and one output for control signals X2 |
LED MOT | Motor active; 2 yellow LEDs |
Climatic conditions | For indoor use only |
Compatible roller motors | Interroll EC310, Interroll EC5000, Itoh Denki PM500XK, Rulmeca BL3 |
Physical | M12 connector, 4-pin Electronic output: PNP, overload and short-circuit proof (X2OUT) Input: PNP, galvanically isolated, potential-free (X2IN) |
Input filter | 10 ms |
Rated operating current | ≤ 30 mA (Closed-circuit current) max. 10 A (<2 s) |
Emitted interference | EN 61000-6-4:2007 |
LED ERR | Motor fault; 2 yellow LEDs yellow: motor error flashing yellow: motor protection unit defective |
Motor fault | NPN digital input, U0 = 14 V, Ri = 34 kΩ 0 (no error) ≥ 125 µA 1 (error) ≤ 25 µA |
Rotation direction signal | low: high impedance high; ≥ (UPWR - 1.0 V) in no-load operation Ri = 5.6 kΩ, RLOAD ≥ 5 kΩ Control using rotary switch S2 |
LED PWR | Supply voltage UPWR; green LED |
Rated operating voltage | 18 V ... 30 V DC PELV (via UPWR) |
Ambient temperature | -30 ... 60 В°C (-22 ... 140 В°F) |
LED IN | switching state (input); 2 LED yellow |
Storage temperature | -30 ... 85 В°C (-22 ... 185 В°F) |
Switching point | in accordance with DIN EN 61131-2 (type 1) 0 (undamped): ≤ 0.5 mA 1 (damped): ≥ 2 mA |
Supply | via UPWR |
Load current | Input: ≤ 8 mA (internally limited) Output: 10 mA |
Load current | Input: ≤ 8 mA (internally limited) Output: 10 mA |
Note | The flat cable routing is designed for 100 actuation cycles |
UL File Number | E223772 ""For use in NFPA 79 Applications only"" |
Voltage | Input: max. 30 V DC Output (via UPWR): ≥ (UPWR - 2 V) |
Degree of protection | IP65 in accordance with EN 60529 (not certified by UL) |
LED XIN | Zone coupling input active; 2 yellow LEDs |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
Current loading capacity | 500 mA , overload and short-circuit protected |
Input current | ≤ 8 mA (limited internally) |
Switch | S1: motor speed; rotary switch, 10 positions S2: direction of rotation and start/stop ramp; rotary switch, 10 positions S3: operating mode, rotary switch, 10 positions |
People also buy
Comments