Pepperl+Fuchs VBA-2E-G11-I/U/PT100-F
AS-Interface analog module

Pepperl+Fuchs VBA-2E-G11-I/U/PT100-F
  • Addressing jack
  • Function display for bus, internal and external sensor power supply, inputs
  • Supply for inputs from AS-Interface or auxiliary voltage
  • Degree of protection IP68 / IP69K
  • Accuracy В± 0.1 %
  • Integrated shielding
  • Channel-specific input monitoring
  • Inputs for current, voltage or Pt100 temperature sensor
Item Number: VBA-2E-G11-I/U/PT100-F
242.10
-
+
Total price: 242.10
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
UL File NumberE223772
Fieldbus standardEN 62026-2:2013
IO code7
Temperature influenceVoltage/current: 20 ppm/K
Pt100: (10 ppm of indicated temperature [В°C] + 0.003 В°C)/K
Parameter bits (programmable via AS-i)function
ID2 codeD
Rated operating voltage26.5 ... 31.6 V from AS-Interface
LED AS-i/FAULTStatus display; multi-colour LED
Green: normal operation
Red: communication fault
Flashing yellow/red: address 0
Flashing green/red: peripheral fault
Data bits (function via AS-Interface)The transfer of the data value is based on AS-Interface Profile 7.3.
MountingMounting plate
Emitted interferenceEN 61000-6-4:2007
Climatic conditionsFor indoor use only
Mission Time (TM)20 a
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Required master specification V2.1
AS-InterfaceEN 62026-2:2013
Rated operating current 60 mA (without sensors) / max. 200 mA
Protection classIII
Tightening torque, cable gland0.4 Nm
LED ANALOGstatus of input signal; LED yellow
off: not active
on: signal within measurement range
flashing: signal outside of measurement range
Current loading capacity 140 mA from AS-Interface; overload and short-circuit resistant
600 mA from external auxiliary voltage UAUX , overload and short-circuit protected
Measuring currentfor Pt100: approx. 1 mA
ID1 codeF
LED INT/EXTstatus display input supply; LED green
green: input supply from AS-Interface
off: input supply from auxiliary voltage
Relative humidity85 % , noncondensing
ID code3
MTTFd190 a
Mass200 g
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Auxiliary voltage (output)20 ... 30 V DC PELV
Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV)
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
Input resistancecurrent input: max. 70 andOmega;
voltage input: 100 kandOmega;
ProfileS-7.3.D
AS-Interface specificationV3.0
Supplyfrom AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT)
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
AccuracyVoltage/current: 0.1% of accumulated value
Pt100: 0.1% of indicated temperature [В°C] + 0.3 В°C
Resolution16 Bit / 1 andmicro;A (current input) or
16 bit / 1 mV (voltage input) or
16 Bit / 0.1В°C (temperature input)
Degree of protectionEN 60529:2000
Pollution degree3
InputEN 61131-2:2007
Degree of protectionIP68 / IP69K
Diagnostic Coverage (DC)0 %
Tightening torque, housing screws1.8 Nm
Number/Type2 analog inputs
Current: 0 ... 20 mA/4 ... 20 mA
voltage: 0 ... 10 V
Pt100: -200 ... 850 В°C
ConnectionAS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black
Inputs: M12 round connector
Altitude 2000 m above MSL
Slave typeStandard slave

Comments

No comments yet

Write a comment