Pepperl+Fuchs VBA-2E2A-G4-ZE/E2
AS-Interface sensor/actuator module
We ship to United States of America!
- Degree of protection IP67
- A/B slave with extended addressing possibility for up to 62 slaves
- Flat or round cable connection (via standardized EEMS base, not included with delivery)
- Cable piercing method for flat cable
- Communication monitoring
- Inputs for 2- and 3-wire sensors
- Power supply of outputs from the external auxiliary voltage
- Supply for inputs from AS-Interface
- Function display for bus, inputs and outputs
- LED indicator for overload on sensor supply
- Detection of output overload
Item Number:
VBA-2E2A-G4-ZE/E2
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
The price and delivery terms is not final. Please check with the manager.
Contact our experts
- Overview +
- Comments +
Current | 1 A per output |
Input current | 8 mA (limited internally) |
Degree of protection | EN 60529:2000 |
UL File Number | E223772 |
Climatic conditions | For indoor use only |
IO code | B |
Voltage | 21 ... 31 V |
Supply | from external auxiliary voltage UAUX |
Mass | 180 g |
Pollution degree | 3 |
Altitude | 2000 m above MSL |
LED PWR/FAULT | dual LED green/red green: AS-Interface voltage red: communication error or address 0 green/red flashing: overload sensor supply or outputs |
AS-Interface | EN 62026-2:2013 |
Tightening torque, housing screws | 0.8 Nm |
ID code | A |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Connection | cable piercing method or terminal compartment yellow flat cable/black flat cable or standard round cable inputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals |
Required master specification | V2.1 |
Degree of protection | IP67 |
Input | EN 61131-2:2007 |
Protection class | III |
Current loading capacity | 100 mA (TB 40 ?°C), 75 mA (TB 60 ?°C), overload-proof and short-circuit protected |
ID2 code | 0 |
Emitted interference | EN 61000-6-4:2001 |
Auxiliary voltage (output) | 24 V DC ?± 15 % PELV |
Switching point | according to DIN EN 61131-2 (Type 2) |
Relative humidity | 85 % , noncondensing |
Profile | S-B.A.0 |
Number/Type | 2 inputs for 2- or 3-wire sensors (PNP), DC |
Voltage | (UAUX - 0.5 V) |
Ambient temperature | -25 ... 60 ?°C (-13 ... 140 ?°F) |
Rated operating current | 30 mA (without sensors) / max. 140 mA |
Noise immunity | EN 61000-6-2:2001 |
Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Data bits (function via AS-Interface) | |
AS-Interface specification | V2.1 |
LED OUT | Switching state (output); 2 LED yellow |
Number/Type | 2 electronic outputs, PNP overload and short-circuit proof |
LED IN | switching state (input); 2 LED yellow |
Mounting | DIN rail or screw mounting |
Parameter bits (programmable via AS-i) | function |
Slave type | A/B slave |
ID1 code | 7 |
Supply | from AS-Interface |
Storage temperature | -25 ... 85 ?°C (-13 ... 185 ?°F) |
Buy Pepperl+Fuchs VBA-2E2A-G4-ZE/E2 with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com offers electrical items wholesale online. We offer a huge industrial automation products list. We ship to every country with the shortest possible terms. We provide discounts of 5% or more to regular customers. We've made it easy for you to find spare parts. We have an individual approach to each client's needs and pay maximum attention to solving them.