Pepperl+Fuchs VBA-2E2A-G4-ZE/E2
AS-Interface sensor/actuator module

Pepperl+Fuchs VBA-2E2A-G4-ZE/E2
  • Degree of protection IP67
  • A/B slave with extended addressing possibility for up to 62 slaves
  • Flat or round cable connection (via standardized EEMS base, not included with delivery)
  • Cable piercing method for flat cable
  • Communication monitoring
  • Inputs for 2- and 3-wire sensors
  • Power supply of outputs from the external auxiliary voltage
  • Supply for inputs from AS-Interface
  • Function display for bus, inputs and outputs
  • LED indicator for overload on sensor supply
  • Detection of output overload
Item Number: VBA-2E2A-G4-ZE/E2
203.01
-
+
Total price: 203.01
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Current1 A per output
Input current 8 mA (limited internally)
Degree of protectionEN 60529:2000
UL File NumberE223772
Climatic conditionsFor indoor use only
IO codeB
Voltage21 ... 31 V
Supplyfrom external auxiliary voltage UAUX
Mass180 g
Pollution degree3
Altitude 2000 m above MSL
LED PWR/FAULTdual LED green/red
green: AS-Interface voltage
red: communication error or address 0
green/red flashing: overload sensor supply or outputs
AS-InterfaceEN 62026-2:2013
Tightening torque, housing screws0.8 Nm
ID codeA
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Connectioncable piercing method or terminal compartment
yellow flat cable/black flat cable or standard round cable
inputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals
Required master specification V2.1
Degree of protectionIP67
InputEN 61131-2:2007
Protection classIII
Current loading capacity 100 mA (TB 40 В°C),
75 mA (TB 60 В°C), overload-proof and short-circuit protected
ID2 code0
Emitted interferenceEN 61000-6-4:2001
Auxiliary voltage (output)24 V DC В± 15 % PELV
Switching pointaccording to DIN EN 61131-2 (Type 2)
Relative humidity85 % , noncondensing
ProfileS-B.A.0
Number/Type2 inputs for 2- or 3-wire sensors (PNP), DC
Voltage (UAUX - 0.5 V)
Ambient temperature-25 ... 60 В°C (-13 ... 140 В°F)
Rated operating current 30 mA (without sensors) / max. 140 mA
Noise immunityEN 61000-6-2:2001
Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV)
Data bits (function via AS-Interface) input output
AS-Interface specificationV2.1
LED OUTSwitching state (output); 2 LED yellow
Number/Type2 electronic outputs, PNP overload and short-circuit proof
LED INswitching state (input); 2 LED yellow
MountingDIN rail or screw mounting
Parameter bits (programmable via AS-i)function
Slave typeA/B slave
ID1 code7
Supplyfrom AS-Interface
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)

Comments

No comments yet

Write a comment