Pepperl+Fuchs VBA-4A-G11-I/U-F
AS-Interface analog module
- Addressing jack
- Degree of protection IP68 / IP69K
- Function display for bus, external auxiliary voltage and outputs
- Supply for outputs from AS-Interface or from bulk power
- Accuracy В± 0.15 %
- Current or voltage output
- Integrated shielding
- Channel-specific output monitoring
- Communication monitoring
- Overview
- Comments
Altitude | 2000 m above MSL |
Auxiliary voltage (output) | 24 V DC В± 15 % PELV |
AS-Interface | EN 62026-2:2013 |
Resolution | Voltage output: 3 mV Current output: 6 andmicro;A |
Degree of protection | IP68 / IP69K |
Parameter bits (programmable via AS-i) | function |
Mass | 200 g |
Degree of protection | EN 60529:2000 |
Fieldbus standard | EN 62026-2:2013 |
Rated operating current | 75 mA (without outputs) / max. 200 mA |
Relative humidity | 85 % , noncondensing |
Required master specification | V2.1 |
LED INT/EXT | status display output supply; LED green green: output supply from AS-Interface off: output supply from auxiliary voltage |
ID1 code | F |
Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
ID code | 3 |
Profile | S-7.3.6 |
ID2 code | 6 |
Climatic conditions | For indoor use only |
Load | voltage output: min. 1 kandOmega; current output: max. 600 andOmega; |
MTTFd | 220 a |
Supply | from AS-Interface (switch position INT, default settings) or auxiliary voltage UEXT (switch position EXT) |
UL File Number | E223772 |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
Current loading capacity | 120 mA (signal current + actuator supply) from AS-Interface; overload and short-circuit protected 700 mA (signal current + actuator supply) from external bulk power supply UAUX, overload and short-circuit protected |
Number/Type | 4 analog outputs Current: 0 ... 20 mA Voltage: 0 ... 10 V |
Emitted interference | EN 61000-6-4:2007 |
Mounting | Mounting plate |
Tightening torque, housing screws | 1.8 Nm |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Mission Time (TM) | 20 a |
Ambient temperature | -25 ... 60 В°C (-13 ... 140 В°F) |
Temperature influence | 1 andmicro;A/K or 0,3 mV/K |
Pollution degree | 3 |
Protection class | III |
LED ANALOG | Status of output signal; yellow LED Yellow: Output value within range Yellow flashing: lead breakage (on current output) or output value out of range |
Diagnostic Coverage (DC) | 0 % |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
AS-Interface specification | V3.0 |
IO code | 7 |
Accuracy | 0.15 % of full-scale value |
LED AS-i/FAULT | Status display; multi-colour LED Green: normal operation Red: communication fault Flashing yellow/red: address 0 Flashing green/red: peripheral fault |
Tightening torque, cable gland | 0.4 Nm |
Data bits (function via AS-Interface) | The transfer of the data value is based on AS-Interface Profile 7.3. |
Connection | AS-Interface/UAUX: cable piercing method, flat cable yellow/flat cable black Outputs: M12 round connector |
Slave type | Standard slave |
Short-circuit current | voltage output: max. 22 mA |