Pepperl+Fuchs VBA-4E-G12-ZAL
AS-Interface sensor module

Pepperl+Fuchs VBA-4E-G12-ZAL
  • A/B slave with extended addressing possibility for up to 62 slaves
  • One-piece housing with stainless steel base
  • Installation without tools
  • Metal threaded inserts with SPEEDCON technology
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Inputs for 2-, 3-, and 4-wire sensors
  • Communication monitoring
  • DIN rail mounting
  • AS-Interface certificate
Item Number: VBA-4E-G12-ZAL
138.46
-
+
Total price: 138.46
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Noise immunityEN 61000-6-2:2005 EN 62026-2:2013
Emitted interferenceEN 61000-6-4:2007
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks
10 g, 16 ms in 6 spatial directions 1000 shocks
UL File NumberE223772
Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
option 2 inputs for 4-wire sensors (PNP), DC
ID codeA
LED INswitching state (input); 4 LED yellow
Signal delay< 1 ms (input/AS-Interface)
Tightening torque, cable gland0.4 Nm
LED PWRAS-Interface voltage; green LED
green: voltage OK
flashing green: address 0
Auxiliary voltage24 V DC В± 15 % PELV
AS-InterfaceEN 62026-2:2013
Parameter bits (programmable via AS-i)function
ID1 code7
Rated operating voltage26.5 ... 31.6 V from AS-Interface
AS-Interface specificationV3.0
Switching pointaccording to DIN EN 61131-2 (Type 2)
MTTFd330 a
Altitude 2000 m above MSL
Required master specification V2.1
Connectioncable piercing method
flat cable yellow
inputs: M12 round connector
InputEN 61131-2
Climatic conditionsFor indoor use only
Protection classIII
Degree of protectionIP67
Data bits (function via AS-Interface) input output
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Degree of protectionEN 60529:2000
Diagnostic Coverage (DC)0 %
Fieldbus standardEN 62026-2:2013
Rated operating current 40 mA
MountingMounting plate
Current loading capacity 600 mA overload and short-circuit resistant
Supplyfrom external auxiliary voltage UAUX
Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral
IO code0
Pollution degree3
Mass200 g
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Slave typeA/B slave
Mission Time (TM)20 a
ID2 code2
ProfileS-0.A.2
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: overload of sensor supply
Input current 8 mA (limited internally)
Relative humidity85 % , noncondensing
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage

Comments

No comments yet