Pepperl+Fuchs VBA-4E-G16-ZEJ
AS-Interface sensor module
- Compact design
- Connections via round connector
- AS-Interface connection via M12 metal threaded insert with SPEEDCON
- Function display for bus and inputs
- Degree of protection IP67 / IP68 / IP69K
- Inputs for 2- and 3-wire sensors
- Supply for inputs from AS-Interface
- Communication monitoring
- Detection of overload on sensor supply
Item Number:
VBA-4E-G16-ZEJ
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Supply | from AS-Interface |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Profile | S-0.A.0 |
UL File Number | E223772 |
ID code | A |
Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
Relative humidity | 85 % , noncondensing |
Degree of protection | EN 60529:2000 |
Switching point | according to DIN EN 61131-2 (Type 2) |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Altitude | 2000 m above MSL |
Noise immunity | EN 61000-6-2:2005 EN 62026-2:2013 |
Voltage | 21 ... 31 V |
MTTFd | 390 a |
IO code | 0 |
Mass | 100 g |
Mounting | screw mounting |
Protection class | III |
Pollution degree | 3 |
Emitted interference | EN 61000-6-4:2007 |
AS-Interface specification | V3.0 |
Input current | 9 mA (limited internally) |
Mission Time (TM) | 20 a |
Degree of protection | IP67 / IP68 / IP69k |
Tightening torque, cable gland | 0.4 Nm (M12 connector), 0.2 Nm (M8 connector) |
ID1 code | 7 |
LED IN | switching state (input); 4 LED yellow |
Diagnostic Coverage (DC) | 0 % |
Rated operating current | 40 mA (without sensors) / max. 240 mA |
Input | EN 61131-2 |
Slave type | A/B slave |
Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks |
Data bits (function via AS-Interface) | |
Current loading capacity | 200 mA (TB 40 В°C), 150 mA (TB 70 В°C), overload-proof and short-circuit protected |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Climatic conditions | For indoor use only |
Fieldbus standard | EN 62026-2:2013 |
ID2 code | 0 |
AS-Interface | EN 62026-2:2013 |
Signal delay | < 1 ms (input/AS-Interface) |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
LED PWR/FAULT | Status display; multi-colour LED Green: normal operation Red: communication fault Flashing yellow/red: address 0 Flashing green/red: sensor supply overload |
Required master specification | V2.1 |
Connection | AS-Interface: M12 x 1 quick disconnect actuators: M8 x 1 quick disconnect |
Parameter bits (programmable via AS-i) | function |