Pepperl+Fuchs VBA-4E-KE5-ZEJQ
AS-Interface sensor/actuator module
- Housing with push-in connection technology and mechanically coded terminal blocks
- Housing width 19 mm, installation in the switch cabinet on DIN mounting rail
- Selectable supply to the sensors: External or from the module
- Function display for bus, internal sensor supply, and inputs
Item Number:
VBA-4E-KE5-ZEJQ
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Degree of protection | IP20 For safety applications: Installation in an enclosure with a minimum protection class of IP54 required |
Pollution degree | 2 |
Emitted interference | EN 61000-6-4:2007 |
Protection class | III |
Number/Type | 4 inputs for 3-wire sensors (PNP), DC |
LED INT | Internal input supply active; LED green |
Degree of protection | EN 60529:2000 |
Data bits (function via AS-Interface) | |
UL File Number | E223772 |
Current loading capacity | 150 mA, overload- and short-circuit protected (INT) |
Relative humidity | 85 % , noncondensing |
Climatic conditions | For indoor use only |
ID2 code | 0 |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Fieldbus standard | EN 62026-2:2013 |
Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
MTBF | 368 a |
ID1 code | 7 |
Signal delay | < 1 ms (input/AS-Interface) |
Parameter bits (programmable via AS-i) | function |
AS-Interface | EN 62026-2:2013 |
Vibration resistance | 0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
Auxiliary voltage (input) | 12 ... 30 V DC PELV |
Input current | 5.6 mA (max.) |
LED FAULT | Fault display; Red LED red: Communication fault or address is 0 red, flashing: Overload, internal input supply |
LED IN | switching state (input); 4 LED yellow |
Voltage | 21 ... 31 V DC (INT) |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Connection | Removable push-in terminals rated connection capacity: rigid: 0.20 mm2 ... 1.5 mm2 flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2 flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2 |
AS-Interface specification | V3.0 |
Surge protection | UEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) |
ID code | A |
Shock and impact resistance | 15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Mass | 110 g |
Profile | S-0.A.0 |
Rated operating current | 35 mA (without sensors) / max. 190 mA |
Required master specification | V3.0 |
Switching point | according to DIN EN 61131-2 (type 1) |
Mounting | DIN mounting rail |
IO code | 0 |
Slave type | A/B slave |
Altitude | 2000 m above MSL |
Input | EN 61131-2:2004 |
People also buy