Pepperl+Fuchs VBA-4E3A-G20-ZEL/M1L-P2
AS-Interface I/O module

Pepperl+Fuchs VBA-4E3A-G20-ZEL/M1L-P2
  • A/B slave with extended addressing possibility for up to 62 slaves
  • Inputs for 3-wire sensors
  • Outputs for DC roller motors (drum motors)
  • Connection of motors and sensors via M8 connectors
  • Configurable start/stop ramps
  • Communication monitoring
  • Power supply of the inputs and outputs from the external auxiliary voltage
  • Function display for bus, external auxiliary voltage, in- and outputs
  • Cable piercing method with gold plated contact pins
Item Number: VBA-4E3A-G20-ZEL/M1L-P2
230.06
-
+
Total price: 230.06
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Rated operating current 35 mA
AS-Interface specificationV3.0
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
Number/Type2 Inputs for 3-wire sensors (PNP), DC
Required master specification V2.1
Cable length1 m
ProfileS-7.A.E
UL File NumberE223772 ""For use in NFPA 79 Applications only""
Overload protectionfuse , I2t = 53.7 A2s
ID1 code6
Degree of protectionIP54 according to EN 60529
ID2 codeE
Current loading capacity500 mA , overload and short-circuit protected
LED PWRAS-Interface voltage; green LED
green: voltage OK
green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing
LED ERRMotor fault: 2 LED yellow
LED MOTMotor active; 2 yellow LEDs
Mass220 g
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Motor faultDigital input NPN, U0 = 3.3 V, Ri = 52 kandOmega;
0 (no error) 40 andmicro;A
1 (error) 30 andmicro;A
Rotation direction signalOff / (UAUX - 1.0 V) at no-load
Ri = 5.6 kandOmega;, RLOAD 5 kandOmega;
AS-Interface data bit D2 = 0: UD = Off
NoteThe flat cable routing is designed for 100 actuation cycles
Fieldbus standardEN 62026-2:2013
Input filter2 ms
Auxiliary voltage (output)18 ... 30 VDC PELV
Slave typeA/B slave
Emitted interferenceEN 61000-6-4:2007
ID codeA
Input current 8 mA (limited internally)
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Ambient temperature-25 ... 60 В°C (-13 ... 140 В°F)
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing
Signal delay< 1 ms (input/AS-Interface)
Compatible roller motorsInterroll EC310, Rulmeca BL3
Switching pointaccording to DIN EN 61131-2
0 (undamped) 0.5 mA
1 (damped) 2.0 mA
Supplyfrom external auxiliary voltage UAUX
LED FUSEMotor power supply; 2 green LEDs
Mounting2 clips with andempty; 8 mm drill hole
Velocity signal1.4 andhellip; 13 V at no-load
Ri = 5.6 kandOmega;, RLOAD 35 kandOmega;
Control via parameter P2:0
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
LED DIRMotor rotation direction; yellow LED
ConnectionAS-Interface, AUX: Insulation piercing technology
Yellow flat cable/black flat cable
Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104
Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)
Matching connector: LM004-Gx1-A or similar
Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded).
Matching connector: NM005-Sx1-B or similar
MTBF98 a
Currentmax. 5 A per motor
LED INswitching state (input); 2 LED yellow
Number/Type2 outputs for DC roller motors (MOT1, MOT2)
Degree of protectionEN 60529:2000
Supplyfrom external auxiliary voltage UAUX
Data bits (function via AS-Interface) input output
InputEN 61131-2:2007
AS-InterfaceEN 62026-2:2013
IO code7

Comments

No comments yet

Write a comment