Pepperl+Fuchs VBA-4E3A-G20-ZEL/M1L-P6
AS-Interface I/O module

Pepperl+Fuchs VBA-4E3A-G20-ZEL/M1L-P6
  • A/B slave with extended addressing possibility for up to 62 slaves
  • Inputs for 3-wire sensors
  • Outputs for DC roller motors (drum motors)
  • Connection of motors and sensors via M8 connectors
  • Configurable start/stop ramps
  • Communication monitoring
  • Power supply of the inputs and outputs from the external auxiliary voltage
  • Function display for bus, external auxiliary voltage, in- and outputs
  • Cable piercing method with gold plated contact pins
Item Number: VBA-4E3A-G20-ZEL/M1L-P6
212.18
-
+
Total price: 212.18
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Emitted interferenceEN 61000-6-4:2007
Number/Type2 Inputs for 3-wire sensors (PNP), DC
LED FUSEMotor power supply; 2 green LEDs
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
LED ERRMotor fault: 2 LED yellow
Rated operating current 35 mA
LED PWRAS-Interface voltage; green LED
green: voltage OK
green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing
Number/Type2 outputs for DC roller motors (MOT1, MOT2)
ID1 code6
ID codeA
UL File NumberE223772 ""For use in NFPA 79 Applications only""
Mass220 g
Compatible roller motorsInterroll EC310, Rulmeca BL3
Input current 8 mA (limited internally)
MTBF98 a
Motor faultDigital input NPN, U0 = 3.3 V, Ri = 52 kandOmega;
0 (no error) 40 andmicro;A
1 (error) 30 andmicro;A
Fieldbus standardEN 62026-2:2013
InputEN 61131-2:2007
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing
Current loading capacity500 mA , overload and short-circuit protected
Mounting2 clips with andempty; 8 mm drill hole
Currentmax. 5 A per motor
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Velocity signal1.4 andhellip; 13 V at no-load
Ri = 5.6 kandOmega;, RLOAD 35 kandOmega;
Control via parameter P2:0
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
LED DIRMotor rotation direction; yellow LED
ProfileS-7.A.E
Degree of protectionIP54 according to EN 60529
Supplyfrom external auxiliary voltage UAUX
Auxiliary voltage (output)18 ... 30 VDC PELV
Input filter2 ms
Supplyfrom external auxiliary voltage UAUX
ID2 codeE
IO code7
Data bits (function via AS-Interface) input output
NoteThe flat cable routing is designed for 100 actuation cycles
Cable length0.35 m
Ambient temperature-25 ... 60 В°C (-13 ... 140 В°F)
Signal delay< 1 ms (input/AS-Interface)
Rotation direction signalOff / (UAUX - 1.0 V) at no-load
Ri = 5.6 kandOmega;, RLOAD 5 kandOmega;
AS-Interface data bit D2 = 0: UD = Off
Overload protectionfuse , I2t = 5.56 A2s
Slave typeA/B slave
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
AS-InterfaceEN 62026-2:2013
LED MOTMotor active; 2 yellow LEDs
Switching pointaccording to DIN EN 61131-2
0 (undamped) 0.5 mA
1 (damped) 2.0 mA
ConnectionAS-Interface, AUX: Insulation piercing technology
Yellow flat cable/black flat cable
Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104
Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)
Matching connector: LM004-Gx1-A or similar
Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded).
Matching connector: NM005-Sx1-B or similar
AS-Interface specificationV3.0
LED INswitching state (input); 2 LED yellow
Required master specification V2.1
Degree of protectionEN 60529:2000

Comments