Pepperl+Fuchs VBA-4E3A-G4-ZE/E2
AS-Interface sensor/actuator module
- Degree of protection IP65
- A/B slave with extended addressing possibility for up to 62 slaves
- Flat or round cable connection (via standardized EEMS base, not included with delivery)
- Cable piercing method for flat cable
- Inputs for 2- and 3-wire sensors
- Power supply of outputs from the external auxiliary voltage
- Power supply of inputs from the module
- Function display for bus, ext. auxiliary voltage, inputs and outputs
- LED indicator for overload on sensor supply
Item Number:
VBA-4E3A-G4-ZE/E2
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Number/Type | 3 electronic outputs, PNP, overload and short-circuit proof |
LED OUT | Switching state (output); 3 LED yellow |
Rated operating current | 40 mA (without sensors) / max. 240 mA |
LED PWR/FAULT | dual LED green/red green: AS-Interface voltage red: communication error or address 0 green/red flashing: overload sensor supply or outputs |
Degree of protection | EN 60529:2000 |
UL File Number | E223772 |
Connection | cable piercing method or terminal compartment yellow flat cable/black flat cable or standard round cable inputs/outputs:M12 x 1.5 cable glands and cage tension spring terminals |
ID1 code | 7 |
Current | 4 A total OUT 1, OUT 2: 2 A per output OUT 3: 1.5 A |
Ambient temperature | -25 ... 60 В°C (-13 ... 140 В°F) |
Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Supply | from external auxiliary voltage UAUX |
ID code | A |
AS-Interface | EN 62026-2:2013 |
Mounting | DIN rail or screw mounting |
Parameter bits (programmable via AS-i) | function |
Required master specification | V2.1 |
ID2 code | 0 |
Degree of protection | IP65 |
LED IN | switching state (input); 4 LED yellow |
LED AUX | ext. auxiliary voltage UAUX ; LED green |
Fieldbus standard | EN 62026-2:2013 |
Auxiliary voltage (output) | 24 V DC В± 15 % PELV |
Current loading capacity | 180 mA (TB 40 В°C), 140 mA (TB 60 В°C), short-circuit protected |
Input current | 9 mA (limited internally) |
Supply | from AS-Interface |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Emitted interference | EN 61000-6-4:2007 |
Slave type | A/B slave |
Data bits (function via AS-Interface) | |
Noise immunity | EN 61000-6-2:2005 |
Pollution degree | 3 |
AS-Interface specification | V3.0 |
Switching point | according to DIN EN 61131-2 (Type 2) |
Climatic conditions | For indoor use only |
Mass | 350 g |
Profile | S-7.A.0 |
Voltage | 21 ... 31 V |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
Voltage | (UAUX - 0.5 V) |
Tightening torque, housing screws | 0.8 Nm |
Input | EN 61131-2:2007 |
Altitude | 2000 m above MSL |
Relative humidity | 85 % , noncondensing |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Protection class | III |
IO code | 7 |
People also buy
Comments
No comments yet