Pepperl+Fuchs VBA-4E3A-KE-ZE/R
AS-Interface sensor/actuator module
- A/B slave with extended addressing possibility for up to 62 slaves
- Housing with removable terminals
- Communication monitoring
- Inputs for 2- and 3-wire sensors
- Isolated relay output
- Addressing jack
- Supply of inputs external or from the module, as required
- Function display for bus, internal input supply, inputs and outputs
Item Number:
VBA-4E3A-KE-ZE/R
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
AS-Interface | EN 62026-2:2013 |
Input | EN 61131-2:2004 |
Slave type | A/B slave |
UL File Number | E106378 |
Input/AS-Interface | none |
Rated operating current | 35 mA (without sensors) / max. 235 mA |
Short-circuit-proof | Contact: 500 A / 40 ms |
Current loading capacity | 150 mA, overload- and short-circuit protected (INT) |
Relative humidity | 85 % , noncondensing |
Switching point | according to DIN EN 61131-2 (Type 2) |
Input/Output | IN1 ... IN4 to O1 ... O3: safe isolation acc. to EN 60947-1, rated insulation voltage 278 V AC |
Signal delay | < 2 ms (input/AS-Interface) |
LED IN | switching state (input); 4 LED yellow |
Parameter bits (programmable via AS-i) | function |
Climatic conditions | For indoor use only |
Required master specification | V2.1 |
Mass | 170 g |
Switching off power | 500 VA |
MTTFd | 330 a |
Galvanic isolation | EN 60947-1 |
Connection | removable terminals rated connection capacity: rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2 for multiple-wire connection with two wires of equal cross-section: flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
Altitude | 2000 m above MSL |
LED OUT | Switching state (output); 3 LED yellow |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
IO code | 7 |
Output/Output | O1 to O2, O3: safe isolation according to EN 60947-1, rated insulation voltage 278 V AC O2 to O3: basic insulation according to EN 60947-1, rated insulation voltage 278 V AC |
AS-Interface specification | V2.1 |
Auxiliary voltage (input) | 12 ... 30 V DC PELV |
Pollution degree | 2 |
Usage category | DC-13 and AC-14 |
ID code | A |
Output/AS-Interface | safe isolation acc. to EN 60947-1, rated insulation voltage 278 V AC |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Ambient temperature | -25 ... 60 В°C (-13 ... 140 В°F) |
Degree of protection | IP20 |
Usage category | EN 60947-5-1 |
LED INT | Internal input supply active; LED green |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
Pollution degree | EN 60947-5-1 |
Signal frequency | 250 Hz |
Noise immunity | EN 61000-6-2:2005 |
Number/Type | 3 relay outputs, normally open |
Emitted interference | EN 61000-6-4:2007 |
ID2 code | 0 |
Surge protection | O1 ... O3: Over voltage category II UEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) |
Supply | none |
Degree of protection | EN 60529:2000 |
Data bits (function via AS-Interface) | |
Switching delay | < 10 ms (AS-Interface/contact) |
Input current | 8 mA (limited internally) |
Diagnostic Coverage (DC) | 0 % |
ID1 code | 7 |
Switching frequency | < 20 Hz (without load) < 0.1 Hz (nominal load) |
Electromagnetic compatibility | NAMUR NE 21: 1998-08 |
Mission Time (TM) | 20 a |
Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
Profile | S-7.A.0 |
LED PWR | AS-Interface voltage; LED green |
Voltage | 21 ... 31 V DC (INT) |
LED FAULT | Fault display; Red LED red: Communication fault or address is 0 red, flashing: Overload, internal input supply |
Tightening torque of clamping screws | 0.5 Nm ... 0.6 Nm |
Mounting | DIN mounting rail |