Pepperl+Fuchs VBA-4E4A-CB10-ZJ/E1J-FL
AS-Interface printed circuit board module

- Integrated communication monitoring function
- Outputs short-circuit and overload proof
- Supply of the inputs and the outputs from AS-Interface
- Function display for bus, inputs and outputs
- Connection via lead

Item Number:
VBA-4E4A-CB10-ZJ/E1J-FL
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Datasheet
- Alternative numbers
- Comments
LED FAULT | error display; LED red red: communication error or address is 0 red flashing: overload of outputs |
AS-Interface | EN 62026-2:2013 |
UL approval | Protection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs. |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
LED IN | switching state (input); 4 LED yellow |
AS-Interface specification | V3.0 |
Voltage | 12 ... 31 V |
Slave type | A/B slave |
Note | This device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired. |
Data bits (function via AS-Interface) | |
Parameter bits (programmable via AS-i) | function |
Degree of protection | IP20 according to EN 60529 |
MTBF | 267 a |
ID2 code | 7 |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
ID1 code | 7 |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
UL File Number | E223772 |
ID code | A |
LED OUT | Switching state (output); 4 LED yellow |
LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
Current | ≤ 100 mA per output, ≤ 100 mA total |
Mass | 33 g |
Surge protection | Ue: overvoltage category II, safe isolated power supplies (PELV) |
Number/Type | 4 electronic outputs, NPN, overload proof and short-circuit proof |
Supply | from AS-Interface |
Fieldbus standard | EN 62026-2:2013 |
Altitude | ≤ 5000 m above MSL |
Protection class | III |
Connection | 200 mm, PVC cable 0.5 mm2 |
Vibration resistance | 0.35 mm 10 ... 57 Hz , 5 g, 57 Hz ... 150 Hz, 10 cycles |
Pollution degree | 2 |
Input current | ≤ 4 mA (limited internally) |
Degree of protection | EN 60529:2000 |
Required master specification | ≥ V3.0 |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Emitted interference | EN 61000-6-4:2007 |
Supply | from AS-Interface |
Voltage | 12 ... 31 V |
Relative humidity | 85 % , noncondensing |
Signal delay | < 1 ms (input/AS-Interface) |
Climatic conditions | For indoor use only |
Profile | S-7.A.7 |
Usage category | DC-1 ""general use"" (ohmic and weak inductive loads in accordance with IEC 60947) |
Number/Type | 4 inputs for mechanical contacts |
Rated operating current | ≤ 40 mA (without inputs/outputs)/max. 160 mA |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface (PELV) |
IO code | 7 |