Pepperl+Fuchs VBA-4E4A-G11-ZAJ/EA2L-F
AS-Interface sensor/actuator module
- Inputs for 2-, 3-, and 4-wire sensors
- Power supply of outputs from the external auxiliary voltage
- Supply of sensors from AS-Interface
- Function display for bus, external auxiliary voltage, in- and outputs
- Red LED per channel, lights up in the event of output overload
- Communication monitoring
- Switchable lead breakage detection (outputs)
- Cable piercing method with gold plated contact pins
- Degree of protection IP68 / IP69K
- AS-Interface POWER24
Item Number:
VBA-4E4A-G11-ZAJ/EA2L-F
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Switching point | according to DIN EN 61131-2 (Type 2) |
Tightening torque, cable gland | 0.4 Nm |
Input/Output | safe isolation, rated insulation voltage 40 V DC |
UL File Number | E223772 |
LED AS-i/FAULT | Status display; multi-colour LED Green: normal operation Red: communication fault Flashing yellow/red: address 0 Flashing green/red: sensor supply i.e. overload or lead interruption outputs |
AS-Interface specification | V3.0 |
Profile | S-7.A.7 |
Slave type | A/B slave |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks |
Altitude | 2000 m above MSL |
LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
ID code | A |
Data bits (function via AS-Interface) | |
Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
ID1 code | 7 |
ID2 code | 7 |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Current loading capacity | 200 mA, overload and short-circuit protected |
Fieldbus standard | EN 62026-2:2013 |
Mass | 200 g |
Mission Time (TM) | 20 a |
MTTFd | 120 a |
Connection | AS-Interface/UAUX: AS-Interface flat cable Inputs/outputs: M12 round connector |
Input | EN 61131-2:2007 |
Output/AS-Interface | safe isolation, rated insulation voltage 40 V DC |
Tightening torque, housing screws | 1.8 Nm |
Degree of protection | IP68 / IP69K |
AS-Interface | EN 62026-2:2013 |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Required master specification | V3.0 |
Voltage | (UAUX - 0.5 V) |
LED IN | switching state (input); 4 LED yellow |
Voltage | 12 ... 31 V |
Signal delay | < 1 ms (input/AS-Interface) |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC |
Protection class | III |
Diagnostic Coverage (DC) | 0 % |
IO code | 7 |
Emitted interference | EN 61000-6-4:2007 |
Degree of protection | EN 60529:2000 |
Current | 2 A per output TB 40 °C: 6 A total TB 70 °C: sum O1 + O2 max. 2 A, sum O3 + O4 max. 2 A |
Auxiliary voltage (output) | 20 ... 30 V DC PELV |
Rated operating current | 40 mA (without sensors) / max. 240 mA |
Supply | from AS-Interface |
Parameter bits (programmable via AS-i) | function |
Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
Mounting | Mounting plate |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Supply | from external auxiliary voltage UAUX |
Relative humidity | 85 % , noncondensing |
LED OUT | switching state (output); 4 LED yellow/red yellow: output active red: output overload or lead interruption |
Rated operating voltage | 18,0 ... 31.6 V from AS-Interface |
Pollution degree | 3 |
Input current | 9 mA (limited internally) |
Climatic conditions | For indoor use only |
People also buy
Comments