Pepperl+Fuchs VBA-4E4A-G11-ZAJ/EA2L-F
AS-Interface sensor/actuator module

Pepperl+Fuchs VBA-4E4A-G11-ZAJ/EA2L-F
We ship to United States of America!
  • Inputs for 2-, 3-, and 4-wire sensors
  • Power supply of outputs from the external auxiliary voltage
  • Supply of sensors from AS-Interface
  • Function display for bus, external auxiliary voltage, in- and outputs
  • Red LED per channel, lights up in the event of output overload
  • Communication monitoring
  • Switchable lead breakage detection (outputs)
  • Cable piercing method with gold plated contact pins
  • Degree of protection IP68 / IP69K
  • AS-Interface POWER24
Item Number: VBA-4E4A-G11-ZAJ/EA2L-F
186.40
-
+
Total price: 186.40
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Switching pointaccording to DIN EN 61131-2 (Type 2)
Tightening torque, cable gland0.4 Nm
Input/Outputsafe isolation, rated insulation voltage 40 V DC
UL File NumberE223772
LED AS-i/FAULTStatus display; multi-colour LED
Green: normal operation
Red: communication fault
Flashing yellow/red: address 0
Flashing green/red: sensor supply i.e. overload or lead interruption outputs
AS-Interface specificationV3.0
ProfileS-7.A.7
Slave typeA/B slave
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks
10 g, 16 ms in 6 spatial directions 1000 shocks
Altitude 2000 m above MSL
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
ID codeA
Data bits (function via AS-Interface) input output
Number/Type4 electronic outputs, PNP, overload and short-circuit proof
ID1 code7
ID2 code7
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Current loading capacity 200 mA, overload and short-circuit protected
Fieldbus standardEN 62026-2:2013
Mass200 g
Mission Time (TM)20 a
MTTFd120 a
ConnectionAS-Interface/UAUX: AS-Interface flat cable
Inputs/outputs: M12 round connector
InputEN 61131-2:2007
Output/AS-Interfacesafe isolation, rated insulation voltage 40 V DC
Tightening torque, housing screws1.8 Nm
Degree of protectionIP68 / IP69K
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Required master specification V3.0
Voltage (UAUX - 0.5 V)
LED INswitching state (input); 4 LED yellow
Voltage12 ... 31 V
Signal delay< 1 ms (input/AS-Interface)
Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
option 2 inputs for 4-wire sensors (PNP), DC
Protection classIII
Diagnostic Coverage (DC)0 %
IO code7
Emitted interferenceEN 61000-6-4:2007
Degree of protectionEN 60529:2000
Current2 A per output
TB 40 В°C: 6 A total
TB 70 °C: sum O1 + O2 max. 2 A, sum O3 + O4 max. 2 A
Auxiliary voltage (output)20 ... 30 V DC PELV
Rated operating current 40 mA (without sensors) / max. 240 mA
Supplyfrom AS-Interface
Parameter bits (programmable via AS-i)function
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
MountingMounting plate
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV)
Supplyfrom external auxiliary voltage UAUX
Relative humidity85 % , noncondensing
LED OUTswitching state (output); 4 LED yellow/red
yellow: output active
red: output overload or lead interruption
Rated operating voltage18,0 ... 31.6 V from AS-Interface
Pollution degree3
Input current 9 mA (limited internally)
Climatic conditionsFor indoor use only

Buy Pepperl+Fuchs VBA-4E4A-G11-ZAJ/EA2L-F with the best possible price and delivery terms on eltra-trade.com

You will find a lot of industrial electrical products on eltra-trade.com. We have the status of the official representative of many European brands. We deliver to any country in the world. Our company is not an official distributor of all brands, but we can offer you competitive prices for all items in our catalog. We provide accurate delivery time information at the very beginning. We are the partner who can trust.

Comments

No comments yet

Write a comment