Pepperl+Fuchs VBA-4E4A-G12-ZAL/EA2L
AS-Interface sensor/actuator module
- One-piece housing with stainless steel base
- Installation without tools
- Metal threaded inserts with SPEEDCON technology
- Flat cable connection with cable piercing technique, variable flat cable guide
- Red LED per channel, lights up in the event of output overload
- Communication monitoring, configurable
- Inputs for 2-, 3-, and 4-wire sensors
- DIN rail mounting
- AS-Interface certificate
- Sensor supply powered by AUX
Item Number:
VBA-4E4A-G12-ZAL/EA2L
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
AS-Interface | EN 62026-2:2013 |
Required master specification | V3.0 |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Auxiliary voltage (output) | 24 V DC В± 15 % PELV |
Tightening torque, cable gland | 0.4 Nm |
Signal delay | < 1 ms (input/AS-Interface) |
Slave type | A/B slave |
Pollution degree | 3 |
LED FAULT | error display; LED red red: communication error or address is 0 red flashing: overload of sensor power supply or outputs |
Degree of protection | IP67 |
Input current | 8 mA (limited internally) |
Switching point | according to DIN EN 61131-2 (Type 2) |
Fieldbus standard | EN 62026-2:2013 |
Supply | from external auxiliary voltage UEXT |
Data bits (function via AS-Interface) | |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Current | 2 A per output 6 A total (TB 40 В°C) 4 A total (TB 70 В°C) |
ID2 code | 7 |
Mission Time (TM) | 20 a |
Mounting | Mounting plate |
Rated operating current | 40 mA |
UL File Number | E223772 |
ID code | A |
Relative humidity | 85 % , noncondensing |
Altitude | 2000 m above MSL |
Voltage | (UAUX - 0.5 V) |
AS-Interface specification | V3.0 |
LED OUT | Switching status (output); 4 yellow/red LEDs Yellow: output active Red: output overload |
Profile | S-7.A.7 |
Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) derived from mains up to 300 V AC line-to-neutral |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC |
Noise immunity | EN 61000-6-2:2005 EN 62026-2:2013 |
Emitted interference | EN 61000-6-4:2007 |
ID1 code | 7 |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
MTTFd | 180 a |
Current loading capacity | 600 mA overload and short-circuit resistant |
IO code | 7 |
Mass | 230 g |
Parameter bits (programmable via AS-i) | function |
LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
Climatic conditions | For indoor use only |
Diagnostic Coverage (DC) | 0 % |
Protection class | III |
Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
Supply | from external auxiliary voltage UAUX |
Degree of protection | EN 60529:2000 |
LED IN | switching state (input); 4 LED yellow |
LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
Connection | Cable piercing method flat cable yellow/flat cable black inputs/outputs: M12 round connector |
Input | EN 61131-2 |
People also buy
Comments
No comments yet