Pepperl+Fuchs VBA-4E4A-G2-ZA/EA2
AS-Interface sensor/actuator module
- AS-Interface certificate
- Degree of protection IP67
- Addressing jack
- Flat cable connection with cable piercing technique, variable flat cable guide
- Communication monitoring
- Inputs for 2-, 3-, and 4-wire sensors
- Power supply of outputs from the external auxiliary voltage
- Supply for inputs from AS-Interface
- Ground connection (FE) possible
- Function display for bus, ext. auxiliary voltage, inputs and outputs
- Detection of overload on sensor supply
- Detection of output overload
Item Number:
VBA-4E4A-G2-ZA/EA2
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Current | 0.5 A per output , 2 A total |
ID2 code | 7 |
LED PWR | AS-Interface voltage; LED green |
Climatic conditions | For indoor use only |
Noise immunity | EN 61000-6-2:2001 |
Data bits (function via AS-Interface) | |
Input | EN 61131-2:2007 |
IO code | 7 |
Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
ID1 code | 7 |
AS-Interface | EN 62026-2:2013 |
Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
Supply | from external auxiliary voltage UAUX |
Degree of protection | IP67 |
Connection | Cable piercing method flat cable yellow/flat cable black inputs/outputs: M12 round connector |
Relative humidity | 85 % , noncondensing |
Degree of protection | EN 60529:2000 |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Tightening torque, cable gland | 0.4 Nm |
Mass | 150 g |
UL File Number | E223772 |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Diagnostic Coverage (DC) | 0 % |
Parameter bits (programmable via AS-i) | function |
Profile | S-7.A.7 |
Voltage | 21 ... 31 V |
Pollution degree | 3 |
Altitude | 2000 m above MSL |
Voltage | (UAUX - 0.5 V) |
AS-Interface specification | V3.0 |
Emitted interference | EN 61000-6-4:2001 |
ID code | A |
Signal delay | < 2 ms (input/AS-Interface) |
Slave type | A/B slave |
Auxiliary voltage (output) | 20 ... 30 V DC PELV |
Rated operating current | 40 mA (without sensors) / max. 220 mA |
LED OUT | Switching state (output); 4 LED yellow |
Supply | from AS-Interface |
Signal frequency | 250 Hz |
Fieldbus standard | EN 62026-2:2013 |
Mission Time (TM) | 20 a |
Input current | 9 mA (limited internally) |
Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC |
Mounting | Mounting plate |
Required master specification | V3.0 |
LED FAULT | error display; LED red red: communication error or address is 0 red flashing: overload of sensor power supply or outputs |
MTTFd | 140 a |
Ambient temperature | -25 ... 60 В°C (-13 ... 140 В°F) |
LED IN | switching state (input); 4 LED yellow |
Current loading capacity | 180 mA (TB 40 В°C), 140 mA (TB 60 В°C), , overload and short-circuit protected |
Protection class | III |
Switching point | according to DIN EN 61131-2 (Type 2) |
LED AUX | ext. auxiliary voltage UAUX ; LED green |
People also buy
Comments
No comments yet