Pepperl+Fuchs VBA-4E4A-G20-ZEJ/M3L-P10
AS-Interface I/O module
- A/B slave with extended addressing possibility for up to 62 slaves
- Inputs for 3-wire sensors
- Outputs for DC roller motors (drum motors)
- Connection of motors and sensors via M8 connectors
- Configurable start/stop ramps
- Communication monitoring
- Power supply of outputs from the external auxiliary voltage
- Supply for inputs from AS-Interface
- Function display for bus, external auxiliary voltage, in- and outputs
- Cable piercing method with gold plated contact pins
Item Number:
VBA-4E4A-G20-ZEJ/M3L-P10
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Relative humidity | 85 % non-condensing |
Compatible roller motors | Itoh Denki PM*XP, Itoh Denki PM*XE |
LED MOT | Motor active; 2 yellow LEDs |
Current | 2 A , max. 5 A (<2 s) per motor |
Auxiliary voltage (output) | 18 ... 30 VDC PELV |
Climatic conditions | For indoor use only |
Number/Type | 2 Inputs for 3-wire sensors (PNP), DC |
Input | EN 61131-2:2007 |
AS-Interface specification | V3.0 |
Fieldbus standard | EN 62026-2:2013 |
Connection | AS-Interface, AUX: Insulation piercing technology Yellow flat cable/black flat cable Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104 Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded) Matching connector: LM004-Gx1-A or similar Outputs: LF005-GS1-B (5-pin, bushing contacts, screw lock, B-coded) Matching connector: LM005-Gx1-B or similar |
Supply | from AS-Interface |
Rotation direction signal | PNP digital output low: high impedance high; (VAUX - 2.5 V) in no-load operation |
Velocity signal | 0 ... 10 V DC Control via parameter P1:0 |
Slave type | A/B slave |
Vibration resistance | 0.35 mm / 2 g 10 ... 1000 Hz |
Emitted interference | EN 61000-6-4:2007 |
Current loading capacity | 100 mA , overload and short-circuit protected |
ID code | A |
Pollution degree | 2 |
Mass | 310 g |
Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks |
Altitude | 2000 m above MSL |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Signal delay | < 1 ms (input/AS-Interface) |
LED DIR | Motor rotation direction; yellow LED |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
LED IN | switching state (input); 2 LED yellow |
Data bits (function via AS-Interface) | |
LED PWR | AS-Interface voltage; green LED green: voltage OK green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing |
Cable length | 1 m |
Input current | 6 mA (internally limited) |
LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
Switching point | according to DIN EN 61131-2 0 (undamped) 0.5 mA 1 (damped) 2.0 mA |
Profile | S-7.A.7 |
Rated operating current | 25 mA (without sensors) / max. 170 mA |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Input filter | 2 ms |
Mounting | 2 clips with andempty; 8 mm drill hole |
Supply | from external auxiliary voltage UAUX |
UL File Number | E223772 ""For use in NFPA 79 Applications only"" |
AS-Interface | EN 62026-2:2013 |
Degree of protection | IP54 according to EN 60529 |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
ID2 code | 7 |
IO code | 7 |
Overload protection | fuse , I2t = 53.7 A2s |
LED FAULT | error display; LED red red: communication error or address is 0 red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing |
Note | The flat cable routing is designed for 100 actuation cycles |
ID1 code | 7 |
Required master specification | V2.1 |
MTBF | 98 a |
LED FUSE | Motor power supply; 2 green LEDs |
Degree of protection | EN 60529:2000 |
Motor start signal | PNP digital output low: high impedance high; (VAUX - 2.5 V) in no-load operation |
Number/Type | 2 outputs for DC roller motors (MOT1, MOT2) |
People also buy
Comments