Pepperl+Fuchs VBA-4E4A-G20-ZEJ/M3L-P9
AS-Interface I/O module

Pepperl+Fuchs VBA-4E4A-G20-ZEJ/M3L-P9
  • A/B slave with extended addressing possibility for up to 62 slaves
  • Inputs for 3-wire sensors
  • Outputs for DC roller motors (drum motors)
  • Connection of motors and sensors via M8 connectors
  • Configurable start/stop ramps
  • Communication monitoring
  • Power supply of outputs from the external auxiliary voltage
  • Supply for inputs from AS-Interface
  • Function display for bus, external auxiliary voltage, in- and outputs
  • Cable piercing method with gold plated contact pins
Item Number: VBA-4E4A-G20-ZEJ/M3L-P9
241.18
-
+
Total price: 241.18
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Rotation direction signalPNP digital output
low: high impedance
high; (VAUX - 2.5 V) in no-load operation
ID2 code7
Altitude 2000 m above MSL
Supplyfrom AS-Interface
Velocity signal0 ... 10 V DC
Control via parameter P1:0
Number/Type2 outputs for DC roller motors (MOT1, MOT2)
Ambient temperature-25 ... 70 В°C (-13 ... 158 В°F)
Data bits (function via AS-Interface) input output
ConnectionAS-Interface, AUX: Insulation piercing technology
Yellow flat cable/black flat cable
Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104
Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded)
Matching connector: LM004-Gx1-A or similar
Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded).
Matching connector: NM005-Sx1-B or similar
Current loading capacity100 mA , overload and short-circuit protected
LED ERRMotor fault: 2 LED yellow
ProfileS-7.A.7
Climatic conditionsFor indoor use only
MTBF98 a
Degree of protectionEN 60529:2000
NoteThe flat cable routing is designed for 100 actuation cycles
LED INswitching state (input); 2 LED yellow
Mounting2 clips with andempty; 8 mm drill hole
LED PWRAS-Interface voltage; green LED
green: voltage OK
green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing
AS-InterfaceEN 62026-2:2013
Current2 A , max. 5 A (<2 s) per motor
Number/Type2 Inputs for 3-wire sensors (PNP), DC
InputEN 61131-2:2007
Signal delay< 1 ms (input/AS-Interface)
Fieldbus standardEN 62026-2:2013
LED FUSEMotor power supply; 2 green LEDs
IO code7
ID1 code7
Emitted interferenceEN 61000-6-4:2007
LED DIRMotor rotation direction; yellow LED
Auxiliary voltage (output)18 ... 30 VDC PELV
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Slave typeA/B slave
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Pollution degree2
Rated operating current 25 mA (without sensors) / max. 170 mA
Motor faultNPN digital input
0 (no error) 125 andmicro;A
1 (error) 25 andmicro;A
Degree of protectionIP54 according to EN 60529
LED AUXext. auxiliary voltage UAUX; dual LED green/red
green: voltage OK
red: reverse voltage
Mass310 g
ID codeA
AS-Interface specificationV3.0
Relative humidity85 % non-condensing
LED MOTMotor active; 2 yellow LEDs
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing
Compatible roller motorsInterroll EC310, Rulmeca BL3
Cable length1 m
Switching pointaccording to DIN EN 61131-2
0 (undamped) 0.5 mA
1 (damped) 2.0 mA
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Overload protectionfuse , I2t = 53.7 A2s
UL File NumberE223772 ""For use in NFPA 79 Applications only""
Vibration resistance0.35 mm / 2 g 10 ... 1000 Hz
Input filter2 ms
Input current 6 mA (internally limited)
Required master specification V2.1
Supplyfrom external auxiliary voltage UAUX
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks

Comments

No comments yet

Write a comment