Pepperl+Fuchs VBA-4E4A-KE-ZE/R
AS-Interface sensor/actuator module

Pepperl+Fuchs VBA-4E4A-KE-ZE/R
We ship to United States of America!
  • Housing with removable, mechanical and color coded terminals
  • Communication monitoring
  • Inputs for 2- and 3-wire sensors
  • Isolated relay output
  • Addressing jack
  • Selectable supply to the sensors: External or from the module
  • Function display for bus, internal sensor supply, inputs, and outputs
Item Number: VBA-4E4A-KE-ZE/R
Price on Request
-
+
Total price: 0.00
Delivery standard: 3-6 weeks, depending on the country.
Condition: new
Contact our experts
  • Overview +
  • Comments +
LED INTInternal input supply active; LED green
Input current 8 mA (limited internally)
Data bits (function via AS-Interface) input output
Auxiliary voltage (input)12 ... 30 V DC PELV
Parameter bits (programmable via AS-i)function
AS-InterfaceEN 62026-2:2013
ID2 code7
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm
LED INswitching state (input); 4 LED yellow
Control circuit 8 mA per relay (from AS-Interface)
Input/AS-InterfaceSwitch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC
Ambient temperature-25 ... 60 ?°C (-13 ... 140 ?°F)
Emitted interferenceEN 61000-6-4:2007
InputEN 61131-2:2004
Degree of protectionIP20
Switching pointaccording to DIN EN 61131-2 (Type 2)
IO code7
Degree of protectionEN 60529:2000
AS-Interface specificationV3.0
ProfileS-7.A.7
MountingDIN mounting rail
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
UL File NumberE106378
Galvanic isolationEN 60947-1:2007
Fieldbus standardEN 62026-2:2013
MTTFd300 a
Current loading capacity 150 mA, overload- and short-circuit protected (INT)
Relative humidity85 % , noncondensing
Mission Time (TM)20 a
Pollution degree2
Usage categoryDC-13 and AC-14
Required master specification V3.0
Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT)
Rated operating current 35 mA (no sensors)/max. 210 mA
Storage temperature-25 ... 85 ?°C (-13 ... 185 ?°F)
Number/Type4 relay outputs, normally open
Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Output/Outputbasic insulation, rated insulation voltage 300 V AC
Rated operating voltage26.5 ... 31.6 V from AS-Interface
LED OUTSwitching state (output); 4 LED yellow
Mass170 g
Diagnostic Coverage (DC)0 %
LED PWRAS-Interface voltage; LED green
Slave typeA/B slave
Climatic conditionsFor indoor use only
ID codeA
Altitude 2000 m above MSL
Voltage21 ... 31 V DC (INT)
Surge protectionO1 ... O4: Over voltage category II
UEXT, Ue: Over voltage category III, safe isolated power supplies (PELV)
Supplynone
Signal delay< 2 ms (input/AS-Interface)
Connectionremovable terminals
rated connection capacity:
rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2
for multiple-wire connection with two wires of equal cross-section:
flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
LED FAULTFault display; Red LED
red: Communication fault or address is 0
red, flashing: Overload, internal input supply
Output/AS-Interfacesafe isolation, rated insulation voltage 300 V AC
Switching delay< 10 ms (AS-Interface/contact)
Input/Outputsafe isolation, rated insulation voltage 300 V AC
ID1 code7

Buy Pepperl+Fuchs VBA-4E4A-KE-ZE/R with the best possible price and delivery terms on eltra-trade.com

Find the industrial control components you need at eltra-trade.com. Our catalog includes a variety of sizes and types, all available for fast delivery. Enjoy competitive pricing and excellent customer service. Trust us to fulfill your automation equipment requirements.

Comments

No comments yet

Write a comment