Pepperl+Fuchs VBA-4E4A-KE5-ZEJQ/E2L
AS-Interface sensor/actuator module
- Housing with push-in connection technology and mechanically coded terminal blocks
- Housing width 19 mm, installation in the switch cabinet on DIN mounting rail
- Selectable supply to the sensors: External or from the module
- Function display for bus, external auxiliary voltage, internal sensor supply, inputs, and outputs
- Red LED per channel, lights up in the event of output overload
Item Number:
VBA-4E4A-KE5-ZEJQ/E2L
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Rated operating current | 35 mA (without sensors) / max. 190 mA |
Shock and impact resistance | 15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
Current | 2 A Per output, total 4 A (TB 60 В°C) 1 A Per output, total 4 A (TB 70 В°C) |
LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
Required master specification | V3.0 |
Electrical safety | IEC 61140:2009 |
Relative humidity | 85 % , noncondensing |
Input current | 5.6 mA (max.) |
Functional safety | EN ISO 13849-1:2008 EN ISO 13849-2:2012 |
Slave type | A/B slave |
UL File Number | E223772 |
ID2 code | 7 |
Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
Degree of protection | EN 60529:2000 |
LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
Vibration resistance | 0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
Current loading capacity | 150 mA, overload- and short-circuit protected (INT) |
Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
LED OUT | switching state (output); 4 LED yellow/red yellow: output active red: output overload or lead interruption |
LED IN | switching state (input); 4 LED yellow |
Profile | S-7.A.7 |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Input | EN 61131-2:2004 |
LED INT | Internal input supply active; LED green |
Emitted interference | EN 61000-6-4:2007 |
MTBF | 141 a |
LED FAULT | Error display; red LED red: communication error, i.e. address is 0 red flashing: overload internal input supply, i.e. overload or lead interruption outputs |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Protection class | III |
Signal delay | < 1 ms (input/AS-Interface) |
Fieldbus standard | EN 62026-2:2013 |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
Parameter bits (programmable via AS-i) | function |
AS-Interface specification | V3.0 |
Pulse withstand voltage | 0.8 kV |
Switching point | according to DIN EN 61131-2 (type 1) |
Number/Type | 4 inputs for 3-wire sensors (PNP), DC |
AS-Interface | EN 62026-2:2013 |
ID code | A |
Surge protection | UEXT, UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) Overvoltage category of the power supplies (primary): III |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
Rated insulation voltage | 92 V |
Mass | 110 g |
Climatic conditions | For indoor use only |
Auxiliary voltage (output) | 20 ... 30 V DC PELV |
Altitude | 2000 m above MSL |
Auxiliary voltage (input) | 12 ... 30 V DC PELV |
Data bits (function via AS-Interface) | |
Usage category | DC-13 |
Connection | Removable push-in terminals rated connection capacity: rigid: 0.20 mm2 ... 1.5 mm2 flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2 flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2 |
Voltage | (UAUX - 0.5 V) |
Supply | from external auxiliary voltage UAUX |
IO code | 7 |
Pollution degree | 2 |
ID1 code | 7 |
Voltage | 21 ... 31 V DC (INT) |
Degree of protection | IP20 For safety applications: Installation in an enclosure with a minimum protection class of IP54 required |
Mounting | DIN mounting rail |