Pepperl+Fuchs VBA-4E4E-G11-ZAJ-F
AS-Interface sensor module
- Inputs for 2-, 3-, and 4-wire sensors
- Supply of sensors from AS-Interface
- Function display for bus and inputs
- Degree of protection IP68 / IP69K
- Communication monitoring
- Cable piercing method with gold plated contact pins
- AS-Interface POWER24
Item Number:
VBA-4E4E-G11-ZAJ-F
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Tightening torque, housing screws | 1.8 Nm |
Relative humidity | 85 % , noncondensing |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
MTTFd | 120 a |
Current loading capacity | 200 mA, overload and short-circuit protected |
Signal delay | < 1 ms (input/AS-Interface) |
UL File Number | E223772 |
ID1 code | Slave 1 1 |
AS-Interface | EN 62026-2:2013 |
Voltage | 12 ... 31 V |
Degree of protection | IP68 / IP69K |
Input current | 9 mA (limited internally) |
Mass | 200 g |
Diagnostic Coverage (DC) | 0 % |
Switching point | according to DIN EN 61131-2 (Type 2) |
Mounting | Mounting plate |
LED IN | switching state (input); 8 LED yellow |
Data bits (function via AS-Interface) | Input slave 1 |
LED AS-i/FAULT | 2 Dual LEDs green/red green: AS-Interface voltage red: Communication error yellow/red flashing: Address 0 green/red flashing: Sensor supply overload |
Climatic conditions | For indoor use only |
Emitted interference | EN 61000-6-4:2007 |
Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) |
Protection class | III |
Mission Time (TM) | 20 a |
Degree of protection | EN 60529:2000 |
ID2 code | 2 |
Fieldbus standard | EN 62026-2:2013 |
Parameter bits (programmable via AS-i) | function |
Tightening torque, cable gland | 0.4 Nm |
Connection | AS-Interface: AS-Interface flat cable Inputs: M12 round connector |
Rated operating current | 80 mA (without sensors) / max. 280 mA |
Pollution degree | 3 |
Ambient temperature | -25 ... 70 В°C (-13 ... 158 В°F) |
IO code | 0 |
Shock and impact resistance | 30 g, 6 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
Required master specification | V2.1 |
Supply | from AS-Interface |
Rated operating voltage | 18,0 ... 31.6 V from AS-Interface |
Altitude | 2000 m above MSL |
ID code | A |
AS-Interface specification | V3.0 |
Profile | S-0.A.2 |
Number/Type | 2x 4 inputs for 2- or 3-wire sensors (PNP), DC alternative 2x 2 inputs for 4-wire sensors (PNP), DC |
Slave type | A/B slave |
Vibration resistance | 0.35 mm 10 ... 57 Hz , 5 g 57 ... 2000 Hz, 10 cycles |
Input | EN 61131-2:2007 |
People also buy
Comments