  • Gateway and safety monitor in one housing
  • SafeLink
  • Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
  • Six safe electronic outputs
  • Integrated data decoupling
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Connection to CC-Link
Item Number: VBG-CCL-K30-D-S32-EV
Price on Request
-
+
Total price: 0.00
Contact our experts
  • Overview
  • Comments
PLC-Functionalityactivateable
OK buttonMode selection traditional-graphical/confirmation
Transfer rate156 Bit/s up to 10 MBit/s
AS-InterfaceEN 62026-2:2013
UL approvalAn isolated source with a secondary open circuit voltage of 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed.
UL mark does not provide UL certification for any functional safety rating or aspects of the device.
Interface typeChip card slot
Response delay< 40 ms
Safety Integrity Level (SIL)SIL 3
Supplyfrom AUX
Switching thresholdStatic: 4 mA at 24 V. Dynamic: 15 mA at 24 V (T=100 Вµs)
AS-Interfacespring terminals, removable
DisplayIlluminated graphical LC display for addressing and error messages
Performance level (PL)PL e
LED OUTOutput circuit closed; 6 x green LEDs
Physical Screw terminal block, pluggable
Diagnostics functionExtended function via display
Supplyfrom AUX
Mass800 g
AS-Interface specificationV3.0
Noise immunityEN 61000-6-2/AC:2005
LED IN6 x LED green
LED POWERvoltage ON; LED green
Earth fault detectionintegrated
Button MODEMode selection PRJ-operation/save configuration/cursor
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
LED U AS-iAS-Interface voltage; LED green
Functional safetyEN ISO 13849-1:2008/AC:2009, EN ISO 13849-2:2012 (up to PL e), EN 61508:2010 and EN 62061:2005+A1:2013 (up to SIL3)
UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source
Degree of protectionIP20
MTTFd100 a
Safety output6 semiconductor outputs
Output circuits: 6 PNP transistor outputs
Max. contact load:
1.2 ADC-13 at 30 VDC, andSigma; = 7.2 A in total (see derating)
Construction typeLow profile housing
LED AUXext. auxiliary voltage UAUX ; LED green
Switch-on delay< 10 s
Button4
Rated operating voltage26.5 ... 31.6 V from AS-Interface; 24 V DC
LED CONFIG ERRconfiguration error; LED red
Degree of protectionEN 60529:2000
Insulation voltage 500 V
Rated operating currentapprox. 300 mA PELV
LED CC-LinkCC link in operation; LED green
CC Link error; LED red
Protocolaccording to CC-Link specification
ESC buttonMode selection traditional-graphical/cancel
Transfer rate10 MBit/s
Ambient temperature0 ... 55 В°C (32 ... 131 В°F)
Duplicate address detectionfrom AS-Interface slaves
Interface typeRemote device, 2 В– 4 occupied stations (depending on operating mode)
LED PRJ MODEprojecting mode active; LED yellow
LED AS-i ACTIVEAS-Interface operation normal; LED green
Interface typeRJ-45 Ethernet Diagnostic Interface
CC Link5-pin screw terminal
Emitted interferenceEN 61000-6-4:2007/A1:2011
Switch SETSelection and setting of a slave address
LED PRG ENABLEautom. programming; LED green
B10d2.5 E+5
Number/Type6 inputs
Safety: 3 x 2 channels
Or 6 standard inputs
EMC monitoringintegrated