Pepperl+Fuchs VBG-DN-K20-D
AS-Interface gateway
- Gateway compliant with AS-Interface specification 3.0
- Dublicate addressing detection
- Earth fault detection
- AS-Interface noise detection
- Easy commissioning by graphic display
- Commissioning, locally on the gateway or via AS-i Control Tools software
- Fault diagnosis via LEDs and grafic display
- AS-Interface monitor or extended AS-Interface diagnostic read via display
- Ethernet diagnostic interface
Item Number:
VBG-DN-K20-D
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
Ambient temperature | 0 ... 55 В°C (32 ... 131 В°F) |
LED CONFIG ERR | configuration error; LED red |
LED U AS-i | AS-Interface voltage; LED green |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Transfer rate | 19,2 kBit/s |
Construction type | Low profile housing , Stainless steel |
PLC-Functionality | activateable |
Duplicate address detection | from AS-Interface slaves |
Electromagnetic compatibility | EN 61000-6-2:2005, EN 61000-6-4:2001, EN 50295:1999 |
AS-Interface | spring terminals, removable |
Insulation voltage | 500 V |
LED AS-i ACTIVE | AS-Interface operation normal; LED green |
LED POWER | voltage ON; LED green |
OK button | Mode selection traditional-graphical/confirmation |
Interface type | RS 232, serial Diagnostic Interface |
Degree of protection | IP20 |
Diagnostics function | Extended function via display |
Rated operating current | 200 mA from AS-Interface |
UL File Number | E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source |
DeviceNet | 5-pin CombiCon connector according to DeviceNet specification |
LED PRG ENABLE | autom. programming; LED green |
UL approval | An isolated source with a secondary open circuit voltage of 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. |
EAC conformity | TR CU 020/2011 |
Display | Illuminated graphical LC display for addressing and error messages |
Mass | 520 g |
LED MNS | Module/net status; LED green/red |
EMC monitoring | integrated |
LED PRJ MODE | projecting mode active; LED yellow |
Button MODE | Mode selection PRJ-operation/save configuration/cursor |
Degree of protection | EN 60529:2000 |
Switch SET | Selection and setting of a slave address |
AS-Interface specification | V3.0 |
AS-Interface | EN 62026-2:2013 |
Protocol | DeviceNet |
Earth fault detection | integrated |
Rated operating voltage | from AS-Interface |
ESC button | Mode selection traditional-graphical/cancel |
People also buy
Comments
No comments yet