Pepperl+Fuchs VBG-ENX-K20-DMD
AS-Interface gateway

Pepperl+Fuchs VBG-ENX-K20-DMD
  • Gateway compliant with AS-Interface specification 3.0
  • Connection to Ethernet Modbus TCP/IP
  • 2 AS-Interface networks
  • Dublicate addressing detection
  • Integrated webserver
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
  • Integrated switch allows line topology
  • DLR technology supports ring topology
Item Number: VBG-ENX-K20-DMD
1649.43
-
+
Total price: 1649.43
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments

Diagnostics functionExtended function via display

LED AS-i ACTIVEAS-Interface operation normal; LED green
EthernetRJ-45
Rated operating voltagefrom AS-Interface 30 V DC
Mass500 g
Button4
Earth fault detectionintegrated
Degree of protectionEN 60529:2000
UL approvalAn isolated source with a secondary open circuit voltage of 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed.
UL mark does not provide UL certification for any functional safety rating or aspects of the device.
UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source
Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection
AS-Interfacespring terminals, removable
AS-InterfaceEN 62026-2:2013
Ambient temperature0 ... 55 В°C (32 ... 131 В°F)
Insulation voltage500 V
LED POWERvoltage ON; LED green
Construction typeLow profile housing , Stainless steel
MTTFd100 a at 30 В°C
StandardsEN 61000-6-2:2005, EN 61000-6-4:2007 EN 954-1:1996 (up to Kategorie 4), IEC 61508:2001 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e)
Degree of protectionIP20
DisplayIlluminated graphical LC display for addressing and error messages
Electromagnetic compatibilityEN 61000-6-2:2005, EN 61000-6-4:2007
Interface type2 x RJ-45
Interface typeChip card slot
PLC-Functionalityactivateable
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
EMC monitoringintegrated
Rated operating current200 mA from AS-Interface circuit 1
70 mA from AS-Interface circuit 2
LED PRG ENABLEautom. programming; LED green
EAC conformityTR CU 020/2011
ProtocolEtherNet/IP + MODBUS TCP/IP acc. to IEEE 802.3
supports device level ring protocol DLR
LED CONFIG ERRconfiguration error; LED red
Interface typeRS 232, serial
Diagnostic Interface
Transfer rate19,2 kBit/s
LED PRJ MODEprojecting mode active; LED yellow
Duplicate address detectionfrom AS-Interface slaves
AS-Interface specificationV3.0
LED ETHERNETethernet active; LED green
LED U AS-iAS-Interface voltage; LED green

Comments