Pepperl+Fuchs VBG-PB-K30-D-S16
AS-Interface Gateway/Safety Monitor
- Gateway and safety monitor in one housing
- Gateway compliant with AS-Interface specification 3.0
- Connection to PROFIBUS DP
- AS-Interface safety monitor with extended range of functions
- Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
- Memory card for configuration data
- 2 safe output relays and 2 safe electronic outputs
Item Number:
VBG-PB-K30-D-S16
The price is not final. Please check with the manager!
Contact our experts
- Overview
- Comments
AS-Interface specification | V3.0 |
Response delay | < 40 ms |
Duplicate address detection | from AS-Interface slaves |
Button | 4 |
Safety Integrity Level (SIL) | SIL 3 |
Standards | EN 61000-6-2:2005, EN 61000-6-4:2007 EN 954-1:1996 (up to Kategorie 4), IEC 61508:2001 and EN 62061:2005 (up to SIL3) EN 13849:2008 (PL e) |
AS-Interface | spring terminals, removable |
Diagnostics function | Extended function via display |
Electromagnetic compatibility | EN 61000-6-2:2005, EN 61000-6-4:2007 |
LED PROFIBUS | PROFIBUS master detected; LED green |
Rated operating current | 300 mA from AS-Interface |
LED AS-i ACTIVE | AS-Interface operation normal; LED green |
Degree of protection | EN 60529:2000 |
LED EDM/Start | External device monitoring circuit inputs closed, 4x yellow LEDs |
UL approval | An isolated source with a secondary open circuit voltage of 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. |
Switch-on delay | < 10 s |
Fieldbus standard | PROFIBUS according to DIN 19245 Part 3 |
PLC-Functionality | activateable |
LED U AS-i | AS-Interface voltage; LED green |
LED CONFIG ERR | configuration error; LED red |
Transfer rate | 9.6 kBit/s / 12 MBit/s , Automatic baud rate detection |
LED POWER | voltage ON; LED green |
Interface type | RS 232, serial Diagnostic Interface |
MTTFd | 200 a |
Mass | 800 g |
LED PRG ENABLE | autom. programming; LED green |
Earth fault detection | integrated |
AS-Interface | EN 62026-2:2013 |
LED AUX | ext. auxiliary voltage UAUX ; LED green |
Interface type | Chip card slot |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
Rated operating voltage | 26.5 ... 31.6 V from AS-Interface; Output K3 and K4 24 V DC |
Degree of protection | IP20 |
Interface type | RS-485 |
PROFIBUS | Sub-D interface |
UL File Number | E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source |
Ambient temperature | 0 ... 55 В°C (32 ... 131 В°F) |
B10d | 2 E+7 |
Performance level (PL) | PL e |
Safety output | Output circuits 1 and 2: 2 potential-free contacts, max. contact load: 3 ADC-13 at 30 VDC, 3 AAC-15 at 30 VAC Output circuits 3 and 4: 2 PNP transistor outputs max. contact load: 0.5 ADC-13 at 30 VDC |
Number/Type | 4 EDM/Start inputs: EDM: Inputs for the external device monitoring circuits Start: start inputs: Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 andmu;s) |
EMC monitoring | integrated |
Transfer rate | 19,2 kBit/s |
LED PRJ MODE | projecting mode active; LED yellow |
Insulation voltage | 500 V |
Construction type | Low profile housing , Stainless steel |
LED output circuit | Output circuit closed; 4 x green LEDs |
Protocol | PROFIBUS DP V1 |
Display | Illuminated graphical LC display for addressing and error messages |