Pepperl+Fuchs VBG-PN-K20-DMD
AS-Interface gateway
Gateway compliant with AS-Interface specification 3.0
Connection to PROFINET IO
Fault diagnosis via LEDs and grafic display
Easy commissioning by graphic display
- Overview
- Comments
AS-Interfaceremovable spring clamp terminals
AS-Interface monitor or extended AS-Interface diagnostic read via display
Dublicate addressing detection
Earth fault detection
AS-Interface noise detection
All AS-Interface functions possible via Ethernet
Commissioning, locally on the gateway or via AS-i Control Tools software
Ethernet diagnostic interface
2 AS-Interface networks
PROFINET | RJ-45 |
Standards | EN 61000-6-2:2005, EN 61000-6-4:2007 |
UL File Number | E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source |
Degree of protection | EN 60529:2000 |
OK button | Mode selection traditional-graphical/confirmation |
Interface type | PROFINET I / O device (IRT) |
Storage temperature | -25 ... 85 В°C (-13 ... 185 В°F) |
LED U AS-i | AS-Interface voltage; LED green |
AS-Interface | EN 62026-2:2013 |
Electromagnetic compatibility | EN 61000-6-2:2005, EN 61000-6-4:2007 |
LED CONFIG ERR | configuration error; LED red |
MTTFd | 100 a at 30 В°C |
EMC monitoring | integrated |
LED POWER | voltage ON; LED green |
Rated operating voltage | from AS-Interface |
Construction type | Low profile housing , Stainless steel |
Transfer rate | 19,2 kBit/s |
Button MODE | Mode selection PRJ-operation/save configuration/cursor |
ESC button | Mode selection traditional-graphical/cancel |
Switch SET | Selection and setting of a slave address |
Ambient temperature | 0 ... 55 В°C (32 ... 131 В°F) |
Earth fault detection | integrated |
Physical | 2 x RJ-45 |
EAC conformity | TR CU 020/2011 |
Display | Illuminated graphical LC display for addressing and error messages |
Interface type | RS 232, serial Diagnostic Interface |
UL approval | An isolated source with a secondary open circuit voltage of 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device. |
Rated operating current | 200 mA from AS-Interface circuit 1 200 mA from AS-Interface circuit 2 270 mA in total |
Duplicate address detection | from AS-Interface slaves |
Degree of protection | IP20 |
LED AS-i ACTIVE | AS-Interface operation normal; LED green |
AS-Interface specification | V3.0 |
LED PRG ENABLE | autom. programming; LED green |
Transfer rate | 10 MBit/s / 100 MBit/s , Automatic baud rate detection |
Mass | 500 g |
Protocol | Media Redundancy Protocol (MRP) |
Diagnostics function | Extended function via display |
LED PRJ MODE | projecting mode active; LED yellow |
LED ETHERNET | ethernet active; LED green |
Insulation voltage | 500 V |
Interface type | Chip card slot |