Pepperl+Fuchs VBG-PN-K30-DMD-S32-EV
AS-Interface Gateway/Safety Monitor

Pepperl+Fuchs VBG-PN-K30-DMD-S32-EV
  • Gateway and safety monitor in one housing
  • Connection to PROFINET IO
  • SafeLink
  • Certified up to SIL 3 according to IEC 61508 and EN 62061 and up to PLe according to EN 13849
  • 2 AS-Interface networks
  • Six safe electronic outputs
  • Integrated data decoupling
  • Dublicate addressing detection
  • Earth fault detection
  • AS-Interface noise detection
  • Ethernet diagnostic interface
Item Number: VBG-PN-K30-DMD-S32-EV
2657.29
-
+
Total price: 2657.29
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Duplicate address detectionfrom AS-Interface slaves
Number/Type6 inputs
Safety: 3 x 2 channels
Or 6 standard inputs
Diagnostics functionExtended function via display
Performance level (PL)PL e
LED PRG ENABLEautom. programming; LED green
Rated operating currentapprox. 300 mA PELV
Switch-on delay< 10 s
LED IN6 x LED green
Transfer rate100 MBit/s
LED AUXext. auxiliary voltage UAUX ; LED green
Functional safetyEN ISO 13849-1:2008/AC:2009, EN ISO 13849-2:2012 (up to PL e), EN 61508:2010 and EN 62061:2005+A1:2013 (up to SIL3)
Safety output6 semiconductor outputs
Output circuits: 6 PNP transistor outputs
Max. contact load:
1.2 ADC-13 at 30 VDC, andSigma; = 7.2 A in total (see derating)
AS-Interfacespring terminals, removable
UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source
Safety Integrity Level (SIL)SIL 3
LED CONFIG ERRconfiguration error; LED red
Earth fault detectionintegrated
LED OUTOutput circuit closed; 6 x green LEDs
Mass800 g
Button MODEMode selection PRJ-operation/save configuration/cursor
PROFINETRJ-45
Response delay< 40 ms
Interface typeChip card slot
Degree of protectionEN 60529:2000
LED AS-i ACTIVEAS-Interface operation normal; LED green
Degree of protectionIP20
Ambient temperature0 ... 55 В°C (32 ... 131 В°F)
Insulation voltage 500 V
ProtocolMedia Redundancy Protocol (MRP)
LED PRJ MODEprojecting mode active; LED yellow
LED ETHERNETPROFINET master detected; LED green
MTTFd100 a
PLC-Functionalityactivateable
Interface typePROFINET I / O device (IRT)
LED POWERvoltage ON; LED green
LED U AS-iAS-Interface voltage; LED green
Switch SETSelection and setting of a slave address
AS-InterfaceEN 62026-2:2013
DisplayIlluminated graphical LC display for addressing and error messages
B10d2.5 E+5
Transfer rate10 MBit/s
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Construction typeLow profile housing
EMC monitoringintegrated
Rated operating voltage26.5 ... 31.6 V from AS-Interface; 24 V DC
Interface typeRJ-45 Ethernet Diagnostic Interface
Noise immunityEN 61000-6-4:2007/A1:2011 EN 61000-6-2/AC:2005
UL approvalAn isolated source with a secondary open circuit voltage of 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed.
UL mark does not provide UL certification for any functional safety rating or aspects of the device.
AS-Interface specificationV3.0
Button4
Physical 2 x RJ-45
OK buttonMode selection traditional-graphical/confirmation
ESC buttonMode selection traditional-graphical/cancel