Pepperl+Fuchs VDM28-15-L-IO/110/115b/122
Distance sensor

Pepperl+Fuchs VDM28-15-L-IO/110/115b/122
  • Distance measurement using object
  • Measuring method PRT (Pulse Ranging Technology)
  • IO-link interface for service and process data
  • Analog output 0/4 mA ... 20 mA
  • Accurate, clear, and reproducible measuring results
  • Minimal black-white difference
Item Number: VDM28-15-L-IO/110/115b/122
515.83
-
+
Total price: 515.83
The price is not final. Please check with the manager!
Contact our experts
  • Overview
  • Comments
Light sourcelaser diode
typ. service life 85,000 h at Ta = +25 В°C
Degree of protectionIP65
ProtocolIO-Link V1.0
Control elements5-step rotary switch for operating modes selection (threshold setting and operating modes)
Diameter of the light spot< 15 mm at a distance of 15 m at 20 В°C
Control elementsSwitch for setting the threshold values
Connection300 mm fixed cable with M12 x 1, 4-pin connector
Signal outputPush-pull output, short-circuit protected, reverse polarity protected
Housing height88 mm
Mission Time (TM)10 a
Measuring methodPulse Ranging Technology (PRT)
Housing width25.8 mm
Function indicator2 LEDs yellow for switching state
Interface typeIO-Link
MTTFd200 a
Light typemodulated visible red light
Diagnostic Coverage (DC)0 %
Housing depth54.6 mm
Measurement range0.2 ... 15 m
Operating voltage10 ... 30 V DC / when operating in IO-Link mode: 18 ... 30 V
Process data witdh16 bit