Pepperl+Fuchs WCS2B-LS311
Read head
- SSI interface
- Non-contact, absolute position encoder
- Automatic detection of dirt accumulation
- Overview
- Comments
MTTFd | 60 a |
Operating voltage | 10 ... 30 V DC |
CSA approval | cCSAus Certified, General Purpose Class 2 power source |
Operating temperature | 0 ... 60 В°C (32 ... 140 В°F) with Option H, heating: -40 ... 60 В°C (-40 ... 140 В°F) |
Free tolerances to code rail | horizontal: 10 mm ( В± 5 mm ) vertical: 10 mm ( В± 5 mm ) |
Mass | 500 g |
Clock frequency | 100 ... 1000 kHz |
Connection type | 8-pin, M12 x 1 connector |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms |
Measuring range | max. 327 m |
CCC approval | CCC approval / marking not required for products rated 36 V |
Data output code | Gray code , 25 bit |
Resolution | В± 0.42 mm (1,200 positions/m) |
Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
Power consumption | 2 VA with Option H, heating: 9 VA at 24 V DC |
Ordering information | Mounting plate included with delivery |
Interface type | SSI interface |
Passage speed | 12.5 m/s |
Mission Time (TM) | 10 a |
Relative humidity | 90 % , noncondensing |
Degree of protection | IP54 |
Emitted interference | DIN EN 61000-6-4 |
Diagnostic Coverage (DC) | 0 % |
Noise immunity | DIN EN 61000-6-2 |
People also buy
Comments
No comments yet