Pepperl+Fuchs WCS3B-LS311 Read head


Item Number: WCS3B-LS311
- SSI interface
- Non-contact, absolute position encoder
- Automatic detection of dirt accumulation
- Overview
- Datasheet
- Alternative numbers
- Comments
Passage speed | 12.5 m/s |
Storage temperature | -40 ... 85 В°C (-40 ... 185 В°F) |
Noise immunity | DIN EN 61000-6-2 |
Operation indicator | LED green: power on |
Emitted interference | DIN EN 61000-6-4 |
Connection type | 8-pin, M12 x 1 connector |
Measuring range | max. 314.5 m |
Resolution | В± 0.4 mm (1,250 positions/m) |
Operating voltage | 10 ... 30 V DC |
Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms |
MTTFd | 60 a |
Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |
Ordering information | Mounting plate included with delivery |
Relative humidity | 90 % , noncondensing |
CCC approval | CCC approval / marking not required for products rated 36 V |
Interface type | SSI interface |
Power consumption | 2 VA |
Mission Time (TM) | 10 a |
Degree of protection | IP54 |
Free tolerances to code rail | horizontal: 31 mm ( В± 15.5 mm ) vertical: 28 mm ( В± 14 mm ) |
CSA approval | cCSAus Certified, General Purpose Class 2 power source |
Data flow indicator | LED yellow: data communication active |
Operating temperature | 0 ... 60 В°C (32 ... 140 В°F) |
Diagnostic Coverage (DC) | 0 % |
Data output code | Gray code , 25 bit |
Mass | 500 g |
Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed |
Clock frequency | 100 ... 1000 kHz |
People also buy
Comments
No comments yet